Acesulfame Potassium Powder: E950 Specs, COA & Buying Guide

Acesulfame potassium powder with an E950 specification sheet and COA review checklist for ingredient buyers
Table of Contents

Acesulfame potassium powder is a high-intensity sweetener used in reduced-sugar beverages, dry premixes, bakery products, confectionery, dairy systems and food supplements. Also known as acesulfame K, Ace-K, E950 or INS 950, it is approximately 200 times sweeter than sucrose.

For procurement and quality teams, sweetness intensity is only the starting point. A commercial material should also be evaluated through its chemical identity, dried-basis assay, moisture, impurities, particle size, analytical methods and performance in the intended formulation.

Before approving a bulk order, review the specification and representative certificate of analysis, test a traceable sample and compare the first commercial lot with the approved reference. Current grade and sample information is available on the Essencefield acesulfame potassium powder product page.

Acesulfame Potassium Powder at a Glance

ItemTechnical reference
Common namesAcesulfame potassium, acesulfame K, Ace-K
CAS number55589-62-3
Molecular formulaC₄H₄KNO₄S
Molecular weight201.24 g/mol
Additive referencesE950 and INS 950
Functional classHigh-intensity sweetener and flavor enhancer
Relative sweetnessApproximately 200 times sweeter than sucrose
JECFA assay99.0%–101.0% on the dried basis
Loss on dryingNot more than 1.0%
AppearanceOdorless white crystalline powder

The JECFA specification for acesulfame potassium establishes its international identity and basic purity requirements. The FDA also identifies Ace-K as a non-nutritive sweetener and regulates its use in the United States under 21 CFR 172.800.

Ace-K replaces sweetness but not all the technological functions of sugar. Removing sucrose may also reduce product bulk, body, moisture retention, browning or freeze-point control. Sugar-reduced formulations may therefore require separate texture, solids or bulking systems.

Key Specifications and Application-Specific Controls

A purchasing specification should begin with a recognized compendial standard and then add only the controls required by the application, destination market or customer quality system.

ParameterJECFA referenceWhy it mattersReview action
Assay99.0%–101.0%, dried basisSupports purity and consistent dosage calculationsVerify that the specification and COA use the same assay basis
AppearanceOdorless white crystalline powderHelps detect contamination or abnormal processingCompare the batch with the approved sample
SolubilityFreely soluble in waterAffects premix preparation and liquid processingTest under the intended pH and temperature
Loss on drying≤1.0%Excess moisture can increase clumping and handling variationReview with assay and packaging condition
pH5.5–7.5 in a 1% solutionSupports identity and batch consistencyConfirm the solution concentration and test method
Organic impuritiesPasses the 20 mg/kg UV-active-components testReflects process purificationRequest the method reference and reporting format
Fluoride≤3 mg/kgInternational purity parameterCheck the numerical result and unit
Lead≤1 mg/kgFood-safety and market-access parameterPrefer an actual result to an unexplained “Pass”

Alternative compendial or validated in-house methods may be acceptable when their suitability, reporting limits and relationship to the agreed specification are clear.

Depending on the application, the buyer may also specify particle size, bulk density, solution clarity, additional heavy metals, microbiological limits or packaging requirements. Each test should have a clear safety, regulatory or manufacturing purpose.

How to Review an Ace-K COA

A product specification defines the agreed limits for a selected grade. A certificate of analysis reports the results obtained for one production batch.

A COA should not be approved merely because each row states “Pass.” Its product identity, assay basis, methods and numerical results should be reviewed against the approved purchasing specification.

Verify the Product and Batch

Confirm that the COA contains:

  • Product identity
  • Batch or lot number
  • Manufacturing and retest dates
  • Specification limits
  • Actual results
  • Analytical methods
  • Authorized release information

The batch number should correspond with the package labels, invoice and packing list. When the manufacturer, exporter and commercial supplier are different entities, the production source must remain traceable.

Incorrect chemical identifiers, inconsistent product names or mismatched batch numbers indicate weak document control and should be resolved before material release.

Confirm the Assay Basis

JECFA specifies an acesulfame potassium assay of 99.0%–101.0% on the dried basis.

A dried-basis result excludes the measured moisture content from the purity calculation. An as-is result describes the material in its received condition. The two figures are not directly interchangeable.

Before comparing batches or suppliers, verify:

  • Whether the assay is reported on a dried basis
  • Whether moisture was tested on the same batch
  • Whether the limit and result use the same basis
  • Which analytical method was applied
  • Whether rounding affects a result near the limit

Assay and loss on drying should be assessed together. A batch may meet its chemical-purity requirement while presenting physical handling concerns due to moisture or damaged packaging.

Evaluate Impurities and Heavy Metals

For quantitative parameters, numerical data are generally more useful than a simple compliance statement.

Compare:

  • The approved acceptance limit
  • The reported result
  • The unit of measurement
  • The test method
  • The reporting or quantification limit
  • The laboratory responsible for the test

A result reported as <0.10 mg/kg supports supplier comparison and trend analysis more effectively than an unexplained “Pass.”

Recognize COA Warning Signs

Further review is needed when a COA contains:

  • Incorrect or inconsistent product identity
  • Missing batch or date information
  • No test limits or analytical methods
  • Quantitative tests reported only as “Pass”
  • Identical numerical results across multiple batches
  • Information that conflicts with the packaging or shipping documents

Essencefield’s raw material quality process connects supplier qualification, specification approval, COA review, incoming inspection, material release and batch traceability.

Illustrative COA Review

The example below is for training purposes and does not represent an actual Essencefield batch.

ParameterIllustrative resultReferenceBuyer conclusion
Assay99.4%, dried basis99.0%–101.0%Compliant
Loss on drying0.82%≤1.0%Compliant; monitor the moisture trend
pH, 1% solution6.35.5–7.5Compliant
Lead<0.10 mg/kg≤1 mg/kgCompliant
Organic impuritiesComplies20 mg/kg UV-active-components testConfirm the analytical-method reference
5-chloro-acesulfameNot reportedEFSA 2025 recommendationAsk whether the manufacturing source monitors it

The assay result meets the stated range, but the review should not end there. The loss-on-drying result is compliant but close enough to the limit to justify trend monitoring. The organic-impurity result also requires confirmation of the referenced test method.

2025 EFSA Specification Watch

The European Food Safety Authority re-evaluated acesulfame K in 2025. In addition to its safety assessment, EFSA identified specification issues relevant to ingredient buyers and quality teams.

EFSA recommended that the European Commission consider:

  • A maximum limit of 0.1 mg/kg for 5-chloro-acesulfame, or appropriate genotoxicity data for the impurity
  • A maximum limit of 1 mg/kg for acetylacetamide
  • Lower specification limits for lead and mercury
  • Inclusion of CAS 55589-62-3 in the EU specification

These are scientific recommendations for possible specification revision. They should not be presented as universally adopted statutory limits.

Use JECFA as a baseline international identity and purity reference. Review EFSA’s recommendations when assessing emerging European impurity expectations. Final batch acceptance must follow the destination market’s current law and the buyer’s agreed specification.

For projects affected by European requirements, ask the supplier:

  • Whether 5-chloro-acesulfame and acetylacetamide are monitored
  • Which analytical methods are available
  • What reporting or quantification limits apply
  • Whether additional third-party testing can be arranged
  • How process or production-site changes are controlled

Particle Size and Low-Dose Blend Uniformity

Particle size is not a primary JECFA identity parameter, but it can materially affect factory handling and blend uniformity.

Essencefield’s current product information notes that fine powder and 80–120 mesh options can be discussed. Carrier-based dilution or sweetener premixes may also be evaluated for projects where direct micro-dosing creates a distribution risk.

Particle Compatibility

Fine Ace-K may dissolve rapidly but can create additional dust or segregate from larger carrier particles. Coarser material may handle differently and require a revised premixing process.

Relevant factors include:

  • Particle-size distribution
  • Carrier-particle size
  • Bulk density
  • Powder flow
  • Electrostatic behavior
  • Order of addition
  • Blender design
  • Transport vibration

No single mesh range is ideal for every application. The selected material should be tested in the actual carrier and production system.

Micro-Dosing Control

Because Ace-K is highly potent, small weighing or distribution errors can create noticeable sweetness variation.

Direct addition of a small quantity to a large powder batch may cause:

  • Localized sweetness hotspots
  • Batch-to-batch inconsistency
  • Segregation during handling
  • Uneven tablet or sachet dosage
  • Poor sensory reproducibility

Geometric dilution with a compatible carrier can improve distribution. A validated premix should define the carrier, dilution ratio, mixing sequence, mixing time and sampling procedure.

Formulation Performance

Sweetness Profile

The FDA describes acesulfame potassium as approximately 200 times sweeter than table sugar and notes that it is frequently combined with other sweeteners.

Its perceived potency in a finished product depends on:

  • Product pH
  • Flavor profile
  • Serving temperature
  • Protein and fat
  • Minerals
  • Carbonation
  • Other sweeteners
  • Processing and storage

Ace-K often provides a rapid sweetness response. Excessive levels may create sharp, bitter or metallic notes. It is therefore commonly evaluated with sucralose, aspartame, steviol glycosides, polyols or nutritive sweeteners to modify sweetness onset, peak intensity and aftertaste.

A theoretical sucrose-equivalence calculation can guide initial bench trials, but it should not determine the final commercial dosage.

Sugar-Function Replacement

Ace-K replaces sweetness but does not directly restore:

  • Product bulk
  • Mouthfeel
  • Moisture retention
  • Fermentation
  • Browning
  • Freeze-point control

For example, a bakery formula may require fibers, polyols, starches or other bulking ingredients after sugar reduction. A frozen dessert may need a revised solids and freezing-point system.

Sweetener selection and sugar-function replacement should be treated as separate formulation decisions.

Heat and Acid Stability

Ace-K is commonly selected for thermally processed products. The FDA identifies it as heat stable, including for baked applications.

However, “heat stable” does not mean unconditionally stable under every combination of pH, temperature and holding time. EFSA’s 2025 assessment notes that degradation can occur to some extent at pH below 3 as temperature increases.

Validation should therefore consider:

  • Final product pH
  • Acid type and concentration
  • Heating temperature
  • Holding time
  • Ingredient-addition stage
  • Minerals and other reactive ingredients
  • Packaging process
  • Storage temperature
  • Target shelf life

Chemical retention should not be confused with sensory stability. Even when the sweetener remains present, flavor balance and perceived sweetness can change during storage.

Application Selection Matrix

ApplicationTechnical valueMain riskValidation focus
Beverage systemsHigh sweetness with minimal solidsAftertaste, acid interaction and storage changesSweetener blend, pH, process and shelf life
Dry premixes and sachetsEfficient sweetness in compact formatsSegregation and inaccurate micro-dosingParticle compatibility and blend uniformity
Bakery productsRetains sweetness during many heat processesDoes not replace sugar bulk, moisture or browningVolume, texture, color and water activity
Dairy and frozen dessertsSupports sugar reduction at low inclusion levelsProtein, fat and freezing behavior affect performanceSensory balance and physical stability
Tablets and supplementsUseful for taste maskingUnit-to-unit variation and grade suitabilityPremix uniformity and regulatory review

A practical development process includes four stages:

  1. Define the reference product and sugar-reduction target.
  2. Screen the sweetener blend and solids-replacement system.
  3. Apply the intended production and shelf-life conditions.
  4. Confirm sensory, physical and regulatory performance.

Regulatory Requirements

Safety evaluations, purity specifications, authorized applications and maximum use levels are separate regulatory concepts.

AuthorityWhat it establishesBuyer action
FDAU.S. food-additive status and conditions of useCheck applicable U.S. use and labeling requirements
JECFAInternational safety evaluation and purity monographUse as a technical reference for identity and quality
EFSA and the EUEuropean safety assessment and authorization frameworkVerify current EU category provisions and specifications
Codex AlimentariusInternational category-specific additive provisionsConfirm the food category, notes and national adoption

JECFA and EFSA have established acceptable daily intake values of up to 15 mg/kg body weight per day. An ADI is a lifetime exposure benchmark used in risk assessment; it is not a recommended formulation dosage.

The Codex GSFA entry for INS 950 contains category-specific provisions rather than a single maximum level for every product.

When reviewing a legal use level, confirm:

  • The correct food category
  • Whether the limit applies to the product as sold or consumed
  • Relevant Codex or regulatory notes
  • Combined-sweetener provisions
  • National or regional implementation
  • Current labeling requirements

International standards are valuable references, but the law of the market where the finished product is sold remains controlling.

Supplier and First-Lot Qualification

A supplier should be evaluated through technical compliance, production traceability, documentation quality, application support and repeat-order performance.

Confirm whether the seller is the original manufacturer or an intermediary. In either case, the actual production facility and batch source should remain identifiable.

Documentation Review

A practical qualification package includes:

  • Specification and representative COA
  • TDS and SDS
  • Allergen and GMO statements
  • Origin and manufacturing information
  • Packaging and shelf-life information
  • Facility certificates and additional test reports

Certification should be checked against the certificate holder, manufacturing-site address, product scope, issuing body and validity period.

Essencefield’s testing and certification support is coordinated according to the proposed ingredient, production source, selected facility and project requirements. Documentation coverage should therefore be verified for the specific grade rather than assumed from a general company statement.

Sample and First-Lot Validation

A defensible approval sequence is:

  1. Review the specification and representative COA.
  2. Confirm the manufacturing source and document package.
  3. Test a traceable qualification sample.
  4. Complete bench and pilot-production trials.
  5. Compare the first commercial lot with the approved reference.
  6. Retain samples and approval records.

The first commercial batch should not automatically be assumed to match a pre-sales sample. Compare its identity, critical analytical results, physical behavior and sensory performance with the approved material.

Change Control

Advance notification should be required for changes involving:

  • Production site or legal manufacturer
  • Production process or raw-material source
  • Specification or analytical method
  • Particle size or packaging
  • Country of origin or regulatory status

The expected impact determines whether the changed material requires document review, laboratory testing, formulation trials or complete requalification.

Packaging, Shelf Life and Commercial Evaluation

Essencefield’s current Ace-K product information lists small sealed foil bags or HDPE bottles for samples. Common bulk packing uses a food-grade polyethylene inner liner with an outer carton, fiber drum or kraft bag, commonly referenced at 25 kg per package.

The published shelf-life reference is up to 36 months under sealed, cool and dry conditions, subject to the confirmed grade, batch and packaging.

After opening, the material should be promptly resealed and handled with clean, dry tools. Warehouse controls should protect it from humidity, damaged packaging, cross-contamination and strong odors.

MOQ, sample quantity, lead time, packaging and additional testing are confirmed according to the specification, order quantity and documentation requirements.

Commercial evaluation should consider more than price per kilogram:

  • Delivered ingredient cost
  • Required formulation dosage
  • Testing and premix costs
  • Batch-rejection or inconsistency risk
  • Lead time and safety-stock requirements

A lower quotation may produce a higher finished-product cost if documentation gaps, particle mismatch or batch variability require additional testing or formula adjustment.

Sourcing Acesulfame Potassium Powder

Essencefield supports B2B ingredient projects through specification review, sample coordination, document preparation, packaging confirmation and commercial supply planning.

Its ingredient sourcing service helps buyers compare proposed sources and specifications before sample testing or bulk approval.

Current published support for Ace-K includes:

  • Fine powder and discussable 80–120 mesh options
  • Pure powder without a standard carrier
  • Carrier-based premix evaluation for suitable projects
  • Laboratory sample support
  • Common 25 kg bulk-pack references
  • Shelf-life reference up to 36 months
  • Specification, COA, TDS and SDS coordination
  • Additional testing based on project requirements

A useful sourcing request should state:

  • Intended application
  • Destination market
  • Required assay or standard
  • Preferred particle size
  • Estimated quantity
  • Packaging requirement
  • Required documents
  • Additional test items
  • Sample purpose
  • Project schedule

Submit these details through the Essencefield project inquiry form so the proposed grade, documentation, sample plan and commercial requirements can be reviewed before qualification.

Conclusion

Acesulfame potassium powder is an efficient high-intensity sweetener, but successful sourcing requires more than confirming its approximate 200-times sweetness potency.

Verify the material identity, dried-basis assay, moisture, impurities, particle characteristics and analytical methods. Test low-dose distribution and finished-product performance under the intended process and shelf-life conditions.

The strongest approval process combines document review, a traceable qualification sample, pilot validation and comparison of the first commercial lot with the approved reference.

Request a Manufacturing Quote

Please use the form below to share your ingredient requirements—product category, target application, desired specifications (e.g., assay/ratio, mesh size, carrier), and estimated order quantity. If you need OEM/private label, include dosage form and key label claims. We’ll route your request to the right team and recommend suitable ingredients, testing/documentation options, packaging, and lead times. You’ll receive indicative pricing, MOQ, and a sample/approval plan.

Picture of Essencefield Editorial Team | Ingredient Science, Quality & OEM Manufacturing

Essencefield Editorial Team | Ingredient Science, Quality & OEM Manufacturing

We publish technical guides for B2B sourcing and formulation of botanical ingredients, including typical COA/Spec ranges, risk-based testing plans, documentation, and OEM/private-label manufacturing. Content is reviewed to align with manufacturing feasibility, batch traceability, and quality control practices used for global export projects.

Reviewed By: Essencefield QA & Technical Team (Quality System)

Documents (on request): COA · TDS/Spec · SDS · Allergen/GMO statements · Regulatory declarations (market-dependent)

More Posts