Ethylparaben powder is a crystalline antimicrobial preservative identified by CAS 120-47-8. It is commonly evaluated for cosmetics, personal care products, topical preparations, pharmaceutical projects and other applications where its use is permitted.

For B2B buyers, confirming the chemical name and assay is only the beginning. A commercially suitable material should also meet agreed limits for impurities, moisture and residual solvents, perform reliably in the intended formulation and arrive with complete batch documentation.

This guide explains how to define an ethylparaben specification, review a Certificate of Analysis, manage limited water solubility and qualify a bulk supplier before purchase approval.

Ethylparaben Powder Supply Overview

ItemTechnical or purchasing information
Product nameEthylparaben Powder
Chemical nameEthyl 4-hydroxybenzoate
Alternative nameEthyl p-hydroxybenzoate
CAS number120-47-8
Molecular formulaC₉H₁₀O₃
Molecular weightApproximately 166.17 g/mol
Typical appearanceWhite or nearly white crystalline powder
Primary functionAntimicrobial preservative
Main formulation issueLimited aqueous solubility
Main purchasing issueGrade, impurity control and application fit
Core documentsSpecification, batch COA, TDS and SDS
Commercial detailsSample, MOQ, packaging and lead time confirmed by quotation

The PubChem Ethylparaben record identifies the substance as ethyl 4-hydroxybenzoate under CAS 120-47-8 and lists the molecular formula as C₉H₁₀O₃.

Public databases establish chemical identity. The agreed commercial specification and lot-specific COA should remain the basis for batch acceptance.

Identity and Preservative Function

Ethylparaben is the ethyl ester of 4-hydroxybenzoic acid and belongs to the paraben family of preservatives. Related materials include methylparaben, propylparaben and their salt or blended forms.

Its purpose is to help limit the growth of susceptible microorganisms in formulations that may otherwise deteriorate during manufacturing, storage or use.

The U.S. Food and Drug Administration lists ethylparaben among the parabens commonly used in cosmetics. FDA explains that preservatives help control harmful bacteria and mold and that parabens are frequently combined with other preservatives to provide wider microbial protection.

The amount added to a batch does not by itself determine preservative performance. Effectiveness also depends on:

  • Dissolution and distribution
  • Finished-product pH
  • Oil–water partitioning
  • Surfactants and solubilizers
  • Polymers, proteins and suspended solids
  • Packaging and consumer-use conditions
  • Chemical stability throughout shelf life

A raw material can meet assay requirements yet perform poorly if it crystallizes, binds to other ingredients or partitions into a phase where it is less microbiologically available.

Reference Properties and Commercial Specifications

Published monographs and databases provide useful reference properties, but they should not be copied directly into a purchase specification without reviewing the intended grade and test method.

PropertyReference purposeCommercial purchasing requirement
IdentityConfirms the correct chemical substanceMatch the name, CAS number and identification method
AppearanceSupports visual examinationDefine an acceptable color and physical form
AssayMeasures principal component contentSpecify the method, reporting basis and limit
Melting rangeSupports identity and purity reviewConfirm whether it is a release test
Related substancesIndicates process or degradation impuritiesEstablish individual and total limits
Loss on dryingIndicates moisture and volatile matterSet a suitable maximum
Residue on ignitionScreens for inorganic residueInclude where relevant to the grade
Residual solventsReflects manufacturing-process controlsAlign the test scope with the production route
Particle sizeInfluences handling and incorporationDefine only when it affects the buyer’s process

Assay does not define the complete product

A statement such as “99% ethylparaben powder” does not explain:

  • Which analytical method was used
  • Whether the result is reported as-is or on a dried basis
  • Which related substances are controlled
  • Whether individual impurities have limits
  • Which residual solvents are tested
  • Whether moisture and inorganic residue are controlled
  • Whether particle size is consistent
  • Whether the material meets a named compendial standard

Two batches with similar assay results may behave differently during weighing, premixing, cooling, filtration or long-term storage.

The buyer’s written specification should therefore define the attributes needed for the actual formulation and manufacturing process rather than relying on a supplier’s headline purity.

COA and Batch Quality Review

A specification defines acceptable quality. A Certificate of Analysis reports the test results for one identified batch.

A complete COA should include:

  • Product name and CAS number
  • Batch or lot number
  • Specification limits
  • Actual batch results
  • Analytical methods
  • Manufacturing or release date
  • Retest or expiry date
  • Specification revision
  • Quality-unit authorization

Quantitative tests should normally include numerical results. Reporting every parameter only as “Pass” or “Conforms” makes batch comparison and trend analysis more difficult.

Priority COA tests

TestBuyer review point
IdentificationMethod and result confirm ethylparaben
AssayMethod, reporting basis and acceptance range are stated
Related substancesIndividual and total impurity limits are included
Loss on dryingMoisture or volatile content is controlled
Residue on ignitionInorganic residue meets the agreed limit
Melting rangeResult is consistent with the approved material
Residual solventsTest scope reflects the production process
Particle sizeIncluded when relevant to processing performance

COA warning signs

Further investigation is appropriate when:

  1. Only appearance and assay are reported.
  2. Analytical methods are missing.
  3. The claimed grade does not match the test panel.
  4. The product name and CAS number are inconsistent.
  5. Several batches show implausibly identical numerical results.
  6. Results appear manually changed or lack quality approval.

The supplier COA should be compared with the buyer’s approved specification rather than treated as a standalone guarantee.

Essencefield’s raw material quality process covers supplier qualification, specification confirmation, COA verification, incoming inspection, material release and batch traceability.

Additional analytical or document requirements can be discussed through Essencefield’s Testing & Certifications process. Document availability depends on the ingredient, production source, facility, test scope and batch.

Solubility and Formulation Performance

Limited water solubility is one of the most important practical characteristics of ethylparaben powder.

Direct addition to a cold aqueous phase can cause:

  • Incomplete dissolution
  • Suspended crystals
  • Uneven preservative distribution
  • Haze or sediment
  • Filter residue
  • Recrystallization after cooling
  • Variable assay recovery
  • Reduced antimicrobial availability

A hot premix that initially appears clear may become cloudy or form crystals after cooling. Solubility should therefore be evaluated under both manufacturing and storage conditions.

Formulation-development workflow

A controlled development process should:

  1. Establish the intended use level and legal conditions.
  2. Select a compatible and permitted premix vehicle.
  3. Conduct laboratory-scale solubility screening.
  4. Define the addition point and mixing sequence.
  5. Inspect the formula after cooling.
  6. Monitor crystals, haze and sediment during stability.
  7. Measure pH and preservative content at defined intervals.
  8. Test antimicrobial protection in the final packaging.
  9. Reassess after relevant formula, process or packaging changes.

Suitable incorporation routes may involve a compatible solvent, glycol system or heated phase. The final method should be determined experimentally rather than copied from a generic formulation.

Particle-size considerations

Finer powder may dissolve or disperse more quickly, but it can also increase:

  • Dust generation
  • Electrostatic behavior
  • Weighing loss
  • Operator exposure
  • Powder adhesion to equipment

Coarser particles may be easier to handle but require longer premixing. Particle-size limits should be linked to a real manufacturing need.

Preservation-efficacy testing

A compliant raw material does not prove that the finished product is adequately preserved.

ISO 11930:2019 provides a procedure for evaluating the overall antimicrobial protection of cosmetic products. Its preservation-efficacy test is a reference method for assessing the protection delivered by a cosmetic formulation.

Testing should reflect the final:

  • Formula
  • pH
  • Manufacturing process
  • Packaging
  • Storage conditions
  • Use pattern

A change in fragrance, botanical extract, surfactant, polymer, pH or packaging can alter preservative performance and may require reassessment.

Applications and Regulatory Requirements

The correct ethylparaben grade depends on the finished product, market and buyer specification.

ApplicationMain technical concernMain purchasing concern
Cosmetics and personal careSolubility, pH and challenge-test performanceCosmetic suitability and regional concentration limits
Topical preparationsCompatibility and microbial protectionImpurity profile and documentation
Pharmaceutical projectsExcipient suitability and analytical controlsApplicable monograph and quality system
Laboratory useMethod suitability and traceabilityReagent or reference-material designation
Food-related projectsCategory-specific authorizationApplicable additive law and purity criteria
Industrial formulationsProcessing consistencyContract specification and repeat supply

A laboratory reagent, reference standard and commercial production ingredient are not automatically interchangeable. The product designation, test panel and documentation must match the end use.

Regulatory overview

Authority or marketCurrent positionBuyer action
United States cosmeticsEthylparaben is among the parabens commonly used as cosmetic preservativesEvaluate finished-product safety and labeling
European Union cosmeticsEthylparaben is included in Annex V conditions for methyl- and ethylparabensCalculate concentration as acid and verify current law
WHO/JECFAEthyl p-hydroxybenzoate is identified as INS 214Confirm authorization by country and food category

FDA states that cosmetic ingredients other than color additives generally do not require FDA approval before marketing. Companies remain responsible for ensuring that cosmetic products are safe and properly labeled.

Under the EU cosmetics framework, the entry covering 4-hydroxybenzoic acid and its methyl and ethyl esters lists a maximum concentration of 0.4% expressed as acid for a single ester and 0.8% expressed as acid for mixtures of the covered esters. Ethylparaben and CAS 120-47-8 are included in that entry. Buyers should consult the current legal text before market approval.

The WHO/JECFA record identifies ethyl p-hydroxybenzoate as preservative INS 214 and records a group acceptable daily intake of 0–10 mg/kg body weight for the sum of the ethyl and methyl esters. This scientific evaluation does not create universal authorization for every food category or country.

Regulatory suitability must be checked for the finished product, use concentration, exposure route and destination market.

Comparison with Related Paraben Options

Ethylparaben is one option within a wider preservative system. Related ingredients should be compared by solubility, antimicrobial performance, processing and regulatory status.

OptionMain differenceWhen to investigate
MethylparabenGenerally offers greater aqueous compatibility than longer-chain parabensWhen premix or water-phase handling is important
PropylparabenLower water solubility and separate regulatory conditionsWhen a different antimicrobial profile is required
Sodium paraben systemMay simplify charging into some aqueous processesWhen manufacturing convenience is a priority

For a focused comparison, review Essencefield’s Methylparaben Powder guide and Propylparaben Powder guide.

Substitution should not be made on a one-to-one weight basis without checking assay basis, molecular form, pH effects, labeling and preservation-efficacy data.

Evaluating a Bulk Ethylparaben Supplier

Supplier qualification should focus on the characteristics that directly affect ethylparaben quality and formulation performance.

Priority supplier checks

  • Is the assay method and reporting basis clearly defined?
  • Are individual and total related substances controlled?
  • Does the residual-solvent panel reflect the manufacturing route?
  • Is the representative sample produced by the intended commercial source?
  • Does sample particle size match routine production?
  • Can the supplier provide results from more than one recent batch?
  • Is packaging suitable for moisture and odor protection?
  • Is sufficient retest period available upon delivery?
  • Are specification or source changes communicated before shipment?
  • Can the supplier support investigations and replacement if a batch fails?

Price per kilogram should not override batch consistency and quality risk. Additional incoming testing, document delays, rejected material or inconsistent formulation behavior can make a low quotation more expensive.

Essencefield Documentation and Supply Coordination

Essencefield is based in Xi’an, China and works with self-owned and long-term partner facilities to support international ingredient and OEM projects. Its published quality process includes source review, specification control, incoming inspection, batch records and COA verification.

For an ethylparaben project, available support may include:

  • Specification review
  • Representative sample coordination
  • Batch-specific COA
  • TDS and SDS
  • Additional testing discussions
  • Packaging and shipment-document review
  • MOQ, pricing and lead-time confirmation
  • Communication with sales, technical and quality teams

The Essencefield contact page allows buyers to request specifications, TDS, COA, samples, MOQ, pricing, lead time and available certification information.

Exact grade, test limits, packaging, sample availability, MOQ and delivery schedule should be documented in the current commercial offer.

RFQ Checklist

A technically complete inquiry should include:

  1. Intended application and destination market
  2. Required grade or contract specification
  3. Assay and related-substance limits
  4. Residual-solvent requirements
  5. Particle-size requirement, where relevant
  6. Trial and commercial quantities
  7. Packaging preference
  8. Required documents and additional testing
  9. Delivery location
  10. Required delivery schedule

The inquiry form can prefill:

  • Product: Ethylparaben Powder
  • CAS: 120-47-8

Clear requirements help suppliers quote comparable materials and reduce the risk of receiving offers based on different grades, methods or documentation packages.

Conclusion

Ethylparaben powder should be approved against a defined end use, specification and batch COA—not against purity or price alone.

Buyers should verify the complete impurity profile, validate dissolution and preservation in the finished formulation and confirm regulatory, documentation and supply conditions before issuing a purchase order.

For specification review, representative batch documents, sample availability or a bulk quotation, submit the required application, grade, quantity, market and testing scope through the Essencefield contact page.

Request a Manufacturing Quote

Please use the form below to share your ingredient requirements—product category, target application, desired specifications (e.g., assay/ratio, mesh size, carrier), and estimated order quantity. If you need OEM/private label, include dosage form and key label claims. We’ll route your request to the right team and recommend suitable ingredients, testing/documentation options, packaging, and lead times. You’ll receive indicative pricing, MOQ, and a sample/approval plan.

Picture of Essencefield Editorial Team | Ingredient Science, Quality & OEM Manufacturing

Essencefield Editorial Team | Ingredient Science, Quality & OEM Manufacturing

We publish technical guides for B2B sourcing and formulation of botanical ingredients, including typical COA/Spec ranges, risk-based testing plans, documentation, and OEM/private-label manufacturing. Content is reviewed to align with manufacturing feasibility, batch traceability, and quality control practices used for global export projects.

Reviewed By: Essencefield QA & Technical Team (Quality System)

Documents (on request): COA · TDS/Spec · SDS · Allergen/GMO statements · Regulatory declarations (market-dependent)

More Posts