Ethylparaben powder is a crystalline antimicrobial preservative identified by CAS 120-47-8. It is commonly evaluated for cosmetics, personal care products, topical preparations, pharmaceutical projects and other applications where its use is permitted.
For B2B buyers, confirming the chemical name and assay is only the beginning. A commercially suitable material should also meet agreed limits for impurities, moisture and residual solvents, perform reliably in the intended formulation and arrive with complete batch documentation.
This guide explains how to define an ethylparaben specification, review a Certificate of Analysis, manage limited water solubility and qualify a bulk supplier before purchase approval.
Ethylparaben Powder Supply Overview
| Item | Technical or purchasing information |
|---|---|
| Product name | Ethylparaben Powder |
| Chemical name | Ethyl 4-hydroxybenzoate |
| Alternative name | Ethyl p-hydroxybenzoate |
| CAS number | 120-47-8 |
| Molecular formula | C₉H₁₀O₃ |
| Molecular weight | Approximately 166.17 g/mol |
| Typical appearance | White or nearly white crystalline powder |
| Primary function | Antimicrobial preservative |
| Main formulation issue | Limited aqueous solubility |
| Main purchasing issue | Grade, impurity control and application fit |
| Core documents | Specification, batch COA, TDS and SDS |
| Commercial details | Sample, MOQ, packaging and lead time confirmed by quotation |
The PubChem Ethylparaben record identifies the substance as ethyl 4-hydroxybenzoate under CAS 120-47-8 and lists the molecular formula as C₉H₁₀O₃.
Public databases establish chemical identity. The agreed commercial specification and lot-specific COA should remain the basis for batch acceptance.
Identity and Preservative Function
Ethylparaben is the ethyl ester of 4-hydroxybenzoic acid and belongs to the paraben family of preservatives. Related materials include methylparaben, propylparaben and their salt or blended forms.
Its purpose is to help limit the growth of susceptible microorganisms in formulations that may otherwise deteriorate during manufacturing, storage or use.
The U.S. Food and Drug Administration lists ethylparaben among the parabens commonly used in cosmetics. FDA explains that preservatives help control harmful bacteria and mold and that parabens are frequently combined with other preservatives to provide wider microbial protection.
The amount added to a batch does not by itself determine preservative performance. Effectiveness also depends on:
- Dissolution and distribution
- Finished-product pH
- Oil–water partitioning
- Surfactants and solubilizers
- Polymers, proteins and suspended solids
- Packaging and consumer-use conditions
- Chemical stability throughout shelf life
A raw material can meet assay requirements yet perform poorly if it crystallizes, binds to other ingredients or partitions into a phase where it is less microbiologically available.
Reference Properties and Commercial Specifications
Published monographs and databases provide useful reference properties, but they should not be copied directly into a purchase specification without reviewing the intended grade and test method.
| Property | Reference purpose | Commercial purchasing requirement |
|---|---|---|
| Identity | Confirms the correct chemical substance | Match the name, CAS number and identification method |
| Appearance | Supports visual examination | Define an acceptable color and physical form |
| Assay | Measures principal component content | Specify the method, reporting basis and limit |
| Melting range | Supports identity and purity review | Confirm whether it is a release test |
| Related substances | Indicates process or degradation impurities | Establish individual and total limits |
| Loss on drying | Indicates moisture and volatile matter | Set a suitable maximum |
| Residue on ignition | Screens for inorganic residue | Include where relevant to the grade |
| Residual solvents | Reflects manufacturing-process controls | Align the test scope with the production route |
| Particle size | Influences handling and incorporation | Define only when it affects the buyer’s process |
Assay does not define the complete product
A statement such as “99% ethylparaben powder” does not explain:
- Which analytical method was used
- Whether the result is reported as-is or on a dried basis
- Which related substances are controlled
- Whether individual impurities have limits
- Which residual solvents are tested
- Whether moisture and inorganic residue are controlled
- Whether particle size is consistent
- Whether the material meets a named compendial standard
Two batches with similar assay results may behave differently during weighing, premixing, cooling, filtration or long-term storage.
The buyer’s written specification should therefore define the attributes needed for the actual formulation and manufacturing process rather than relying on a supplier’s headline purity.
COA and Batch Quality Review
A specification defines acceptable quality. A Certificate of Analysis reports the test results for one identified batch.
A complete COA should include:
- Product name and CAS number
- Batch or lot number
- Specification limits
- Actual batch results
- Analytical methods
- Manufacturing or release date
- Retest or expiry date
- Specification revision
- Quality-unit authorization
Quantitative tests should normally include numerical results. Reporting every parameter only as “Pass” or “Conforms” makes batch comparison and trend analysis more difficult.
Priority COA tests
| Test | Buyer review point |
|---|---|
| Identification | Method and result confirm ethylparaben |
| Assay | Method, reporting basis and acceptance range are stated |
| Related substances | Individual and total impurity limits are included |
| Loss on drying | Moisture or volatile content is controlled |
| Residue on ignition | Inorganic residue meets the agreed limit |
| Melting range | Result is consistent with the approved material |
| Residual solvents | Test scope reflects the production process |
| Particle size | Included when relevant to processing performance |
COA warning signs
Further investigation is appropriate when:
- Only appearance and assay are reported.
- Analytical methods are missing.
- The claimed grade does not match the test panel.
- The product name and CAS number are inconsistent.
- Several batches show implausibly identical numerical results.
- Results appear manually changed or lack quality approval.
The supplier COA should be compared with the buyer’s approved specification rather than treated as a standalone guarantee.
Essencefield’s raw material quality process covers supplier qualification, specification confirmation, COA verification, incoming inspection, material release and batch traceability.
Additional analytical or document requirements can be discussed through Essencefield’s Testing & Certifications process. Document availability depends on the ingredient, production source, facility, test scope and batch.
Solubility and Formulation Performance
Limited water solubility is one of the most important practical characteristics of ethylparaben powder.
Direct addition to a cold aqueous phase can cause:
- Incomplete dissolution
- Suspended crystals
- Uneven preservative distribution
- Haze or sediment
- Filter residue
- Recrystallization after cooling
- Variable assay recovery
- Reduced antimicrobial availability
A hot premix that initially appears clear may become cloudy or form crystals after cooling. Solubility should therefore be evaluated under both manufacturing and storage conditions.
Formulation-development workflow
A controlled development process should:
- Establish the intended use level and legal conditions.
- Select a compatible and permitted premix vehicle.
- Conduct laboratory-scale solubility screening.
- Define the addition point and mixing sequence.
- Inspect the formula after cooling.
- Monitor crystals, haze and sediment during stability.
- Measure pH and preservative content at defined intervals.
- Test antimicrobial protection in the final packaging.
- Reassess after relevant formula, process or packaging changes.
Suitable incorporation routes may involve a compatible solvent, glycol system or heated phase. The final method should be determined experimentally rather than copied from a generic formulation.
Particle-size considerations
Finer powder may dissolve or disperse more quickly, but it can also increase:
- Dust generation
- Electrostatic behavior
- Weighing loss
- Operator exposure
- Powder adhesion to equipment
Coarser particles may be easier to handle but require longer premixing. Particle-size limits should be linked to a real manufacturing need.
Preservation-efficacy testing
A compliant raw material does not prove that the finished product is adequately preserved.
ISO 11930:2019 provides a procedure for evaluating the overall antimicrobial protection of cosmetic products. Its preservation-efficacy test is a reference method for assessing the protection delivered by a cosmetic formulation.
Testing should reflect the final:
- Formula
- pH
- Manufacturing process
- Packaging
- Storage conditions
- Use pattern
A change in fragrance, botanical extract, surfactant, polymer, pH or packaging can alter preservative performance and may require reassessment.
Applications and Regulatory Requirements
The correct ethylparaben grade depends on the finished product, market and buyer specification.
| Application | Main technical concern | Main purchasing concern |
|---|---|---|
| Cosmetics and personal care | Solubility, pH and challenge-test performance | Cosmetic suitability and regional concentration limits |
| Topical preparations | Compatibility and microbial protection | Impurity profile and documentation |
| Pharmaceutical projects | Excipient suitability and analytical controls | Applicable monograph and quality system |
| Laboratory use | Method suitability and traceability | Reagent or reference-material designation |
| Food-related projects | Category-specific authorization | Applicable additive law and purity criteria |
| Industrial formulations | Processing consistency | Contract specification and repeat supply |
A laboratory reagent, reference standard and commercial production ingredient are not automatically interchangeable. The product designation, test panel and documentation must match the end use.
Regulatory overview
| Authority or market | Current position | Buyer action |
|---|---|---|
| United States cosmetics | Ethylparaben is among the parabens commonly used as cosmetic preservatives | Evaluate finished-product safety and labeling |
| European Union cosmetics | Ethylparaben is included in Annex V conditions for methyl- and ethylparabens | Calculate concentration as acid and verify current law |
| WHO/JECFA | Ethyl p-hydroxybenzoate is identified as INS 214 | Confirm authorization by country and food category |
FDA states that cosmetic ingredients other than color additives generally do not require FDA approval before marketing. Companies remain responsible for ensuring that cosmetic products are safe and properly labeled.
Under the EU cosmetics framework, the entry covering 4-hydroxybenzoic acid and its methyl and ethyl esters lists a maximum concentration of 0.4% expressed as acid for a single ester and 0.8% expressed as acid for mixtures of the covered esters. Ethylparaben and CAS 120-47-8 are included in that entry. Buyers should consult the current legal text before market approval.
The WHO/JECFA record identifies ethyl p-hydroxybenzoate as preservative INS 214 and records a group acceptable daily intake of 0–10 mg/kg body weight for the sum of the ethyl and methyl esters. This scientific evaluation does not create universal authorization for every food category or country.
Regulatory suitability must be checked for the finished product, use concentration, exposure route and destination market.
Comparison with Related Paraben Options
Ethylparaben is one option within a wider preservative system. Related ingredients should be compared by solubility, antimicrobial performance, processing and regulatory status.
| Option | Main difference | When to investigate |
|---|---|---|
| Methylparaben | Generally offers greater aqueous compatibility than longer-chain parabens | When premix or water-phase handling is important |
| Propylparaben | Lower water solubility and separate regulatory conditions | When a different antimicrobial profile is required |
| Sodium paraben system | May simplify charging into some aqueous processes | When manufacturing convenience is a priority |
For a focused comparison, review Essencefield’s Methylparaben Powder guide and Propylparaben Powder guide.
Substitution should not be made on a one-to-one weight basis without checking assay basis, molecular form, pH effects, labeling and preservation-efficacy data.
Evaluating a Bulk Ethylparaben Supplier
Supplier qualification should focus on the characteristics that directly affect ethylparaben quality and formulation performance.
Priority supplier checks
- Is the assay method and reporting basis clearly defined?
- Are individual and total related substances controlled?
- Does the residual-solvent panel reflect the manufacturing route?
- Is the representative sample produced by the intended commercial source?
- Does sample particle size match routine production?
- Can the supplier provide results from more than one recent batch?
- Is packaging suitable for moisture and odor protection?
- Is sufficient retest period available upon delivery?
- Are specification or source changes communicated before shipment?
- Can the supplier support investigations and replacement if a batch fails?
Price per kilogram should not override batch consistency and quality risk. Additional incoming testing, document delays, rejected material or inconsistent formulation behavior can make a low quotation more expensive.
Essencefield Documentation and Supply Coordination
Essencefield is based in Xi’an, China and works with self-owned and long-term partner facilities to support international ingredient and OEM projects. Its published quality process includes source review, specification control, incoming inspection, batch records and COA verification.
For an ethylparaben project, available support may include:
- Specification review
- Representative sample coordination
- Batch-specific COA
- TDS and SDS
- Additional testing discussions
- Packaging and shipment-document review
- MOQ, pricing and lead-time confirmation
- Communication with sales, technical and quality teams
The Essencefield contact page allows buyers to request specifications, TDS, COA, samples, MOQ, pricing, lead time and available certification information.
Exact grade, test limits, packaging, sample availability, MOQ and delivery schedule should be documented in the current commercial offer.
RFQ Checklist
A technically complete inquiry should include:
- Intended application and destination market
- Required grade or contract specification
- Assay and related-substance limits
- Residual-solvent requirements
- Particle-size requirement, where relevant
- Trial and commercial quantities
- Packaging preference
- Required documents and additional testing
- Delivery location
- Required delivery schedule
The inquiry form can prefill:
- Product: Ethylparaben Powder
- CAS: 120-47-8
Clear requirements help suppliers quote comparable materials and reduce the risk of receiving offers based on different grades, methods or documentation packages.
Conclusion
Ethylparaben powder should be approved against a defined end use, specification and batch COA—not against purity or price alone.
Buyers should verify the complete impurity profile, validate dissolution and preservation in the finished formulation and confirm regulatory, documentation and supply conditions before issuing a purchase order.
For specification review, representative batch documents, sample availability or a bulk quotation, submit the required application, grade, quantity, market and testing scope through the Essencefield contact page.