L-Ornithine Hydrochloride Powder is a water-soluble amino acid ingredient used in capsules, tablets, sachets, drink powders and multi-ingredient nutrition formulas. A headline purity value alone is not sufficient for supplier approval.
Procurement and QA teams should verify the chemical form, assay basis, identity, specific rotation, moisture, related substances, contaminants, particle size and batch documentation. Formulators must also assess taste, pH, powder flow and compatibility with the intended dosage format.
Essencefield’s L-Ornithine Hydrochloride Powder product page provides current technical and commercial information for sample evaluation and bulk sourcing. Final specifications, methods and supply terms are defined by the approved quotation and lot-specific COA.
Product and Procurement Snapshot
| Item | Current product information |
|---|---|
| Product name | L-Ornithine Hydrochloride Powder |
| Common names | L-Ornithine HCl, L-Ornithine monohydrochloride |
| CAS number | 3184-13-2 |
| Molecular formula | C₅H₁₃ClN₂O₂ |
| Molecular weight | 168.62 g/mol |
| Appearance | White to off-white crystalline powder |
| Grade | Food or supplement ingredient grade according to the agreed specification |
| Typical assay option | High-assay grade; 98.5–101.5% on a dry basis may be available |
| Assay method | HPLC or another agreed validated method |
| Solubility | Readily soluble in water |
| Typical particle size | 60–100 mesh options; custom PSD may be discussed |
| Carrier | Carrier-free supply is typical |
| Typical shelf life | 24 months unopened under recommended storage conditions |
| Sample options | 100 g, 500 g, 1 kg or project-specific packs |
| Pilot quantities | 1–5 kg packs may be available |
| Standard bulk packaging | Typically 25 kg carton drum, fiber drum or export carton |
| Standard MOQ | Typically 25 kg |
| Typical lead time | Commonly 2–4 weeks |
| Document support | COA, specification, TDS, SDS and applicable project documents |
The available assay, particle size, testing package and commercial terms may vary with the selected source, quantity, destination market and project requirements.
What Is L-Ornithine Hydrochloride Powder?
L-Ornithine Hydrochloride Powder is the hydrochloride salt of L-ornithine, a non-proteinogenic amino acid involved in nitrogen metabolism.
The hydrochloride form is produced by combining L-ornithine with hydrochloric acid. The resulting salt is identified by CAS 3184-13-2 and has a molecular weight of 168.62 g/mol. The PubChem record for ornithine hydrochloride reports the molecular formula as C₅H₁₂N₂O₂·HCl, which is equivalent to C₅H₁₃ClN₂O₂.
The FAO/WHO JECFA specification uses the name L-ornithine monochlorohydrate and lists L-ornithine monohydrochloride and 2,5-diaminopentanoic acid hydrochloride as synonyms. It describes the substance as a white crystalline solid or powder that is soluble in water.
Commercial material may be produced from a fermentation-derived or another qualified L-ornithine source, followed by purification, hydrochloride formation, crystallization, drying and particle-size control. Buyers requiring a specific production route should request supporting source and manufacturing declarations. Essencefield’s published product information states that a fermentation-derived source can be confirmed by project.
L-Ornithine HCl should not be confused with free L-ornithine, L-ornithine L-aspartate or other ornithine derivatives. Each form has a different composition, molecular weight, specification and evidence base.
L-Ornithine HCl vs. Free L-Ornithine
L-Ornithine HCl and free L-ornithine contain the same core amino acid but are not equivalent by weight.
The PubChem record for free L-ornithine reports a molecular weight of 132.16 g/mol, compared with 168.62 g/mol for the hydrochloride salt.
The theoretical conversion is:
Free L-ornithine equivalent = L-Ornithine HCl quantity × 0.7838
| L-Ornithine HCl input | Theoretical free L-ornithine equivalent |
| 500 mg | Approximately 392 mg |
| 1,000 mg | Approximately 784 mg |
| 1,500 mg | Approximately 1,176 mg |
| 2,000 mg | Approximately 1,568 mg |
The material’s actual assay must also be included in the calculation.
For example, if a batch is assayed at 99.0% as L-Ornithine HCl:
1,000 mg × 0.990 × 0.7838 = approximately 776 mg free L-ornithine equivalent
This conversion supports quotation comparison, formulation input, study interpretation and label calculation.
The COA should clearly identify:
- whether the result is expressed as L-Ornithine HCl or free ornithine;
- whether it is reported on an as-is or dry basis;
- which analytical method was used;
- the applicable specification range.
Two materials advertised as “99% purity” may not be directly comparable when their test methods or reporting bases differ.
Critical Quality Specifications
A purchasing specification should use measurable acceptance criteria rather than broad descriptions such as “premium,” “high purity” or “food grade.”
| Specification item | Why it matters | What the document should show |
| Identity | Confirms the chemical form | FTIR, HPLC comparison or another approved method |
| Assay | Establishes ingredient content | Substance measured, method and reporting basis |
| Specific rotation | Supports L-form identity | Range, solvent, concentration and temperature |
| Chloride | Supports salt-form verification | Method and acceptable range where required |
| Moisture | Affects assay, flow and stability | Loss on drying or another stated method |
| Related substances | Controls process impurities | Individual and total impurity limits |
| Elemental contaminants | Supports safety qualification | Individual Pb, As, Cd and Hg limits |
| Microbiology | Supports food or supplement use | Numerical limits and specified absence tests |
| Particle size | Affects dissolution and processing | Mesh value or complete PSD requirement |
| Bulk density | Affects filling and blending | Method and acceptable range |
Assay and identity
Assay must identify the substance being quantified and the calculation basis. A result expressed as L-Ornithine HCl is not equivalent to a result expressed as free ornithine.
A complete assay record should state:
- analytical method;
- dry-basis or as-is reporting;
- acceptance range;
- actual batch result;
- moisture correction where applicable.
Essencefield’s current product information lists a typical high-assay option of 98.5–101.5% on a dry basis, with HPLC or another agreed validated method. This is an available specification direction rather than a universal release standard.
The JECFA flavoring specification sets a minimum assay of 96%. That limit applies to the evaluated flavoring specification and should not automatically replace a buyer’s food, supplement or internal purchasing standard.
Identity may be supported by FTIR, chromatographic comparison, specific optical rotation, chloride confirmation or another approved method. Specific rotation results should include the test conditions because solvent, concentration and temperature affect comparability.
Physical performance
Moisture affects assay, flow, filling consistency and storage stability. Loss on drying should therefore be reviewed together with packaging, storage and expected production conditions.
Particle size and bulk density affect:
- dissolution speed;
- dust generation;
- segregation;
- hopper flow;
- capsule fill volume;
- sachet-filling consistency;
- tablet behavior.
Typical 60–100 mesh options are available, while custom PSD and lot-specific bulk-density data may be discussed for capsule, tablet, sachet or beverage-powder projects.
Contaminants and microbiology
Elemental-contaminant limits should address lead, arsenic, cadmium and mercury individually. Appropriate limits depend on the intended application, expected intake, destination market and finished-product risk assessment.
The supplier’s specification should also define relevant microbiological limits, which may include:
- total aerobic plate count;
- yeast and mold;
- Escherichia coli;
- Salmonella;
- Staphylococcus aureus where required.
Essencefield’s current product information states that heavy metals and microbiology are controlled according to the agreed specification, with E. coli and Salmonella listed as negative under the applicable test basis.
How to Evaluate an L-Ornithine HCl COA
A Certificate of Analysis should provide batch-specific evidence that the delivered material meets the approved specification.
The document should identify:
- complete product name and grade;
- batch or lot number;
- specification limits;
- actual batch results;
- analytical methods;
- production or manufacturing date;
- release date;
- expiry or retest date;
- authorized quality approval.
The COA batch number must correspond to the labels on the delivered packaging. A representative COA can support preliminary supplier comparison but does not replace the document issued for the commercial batch.
Prefer numerical results
| Test item | Less useful presentation | More useful presentation |
| Identity | Conforms | FTIR: Conforms |
| Assay | Meets specification | 99.3%, HPLC, dry basis |
| Loss on drying | ≤0.50% | 0.21% |
| Lead | ≤3 ppm | 0.15 ppm, stated method |
| Particle size | Passes | 98.5% through 80 mesh |
The figures above illustrate document presentation and are not Essencefield batch results.
Actual results make batch consistency and proximity to release limits easier to assess. The product name, assay basis, shelf life and storage conditions should also remain consistent across the specification, COA, TDS, SDS and packaging label.
FDA’s dietary supplement CGMP guidance states that a component COA should include a description of the test methods, test limits and actual results. It also requires unique lot identification to support traceability from the supplier through manufacturing and distribution.
Essencefield’s raw-material quality process covers supplier qualification, specification approval, COA review, incoming inspection, material release and batch traceability. Its testing and certification support also describes batch documents and third-party laboratory coordination.
Grade, Application and Formulation Fit
Ingredient purity alone does not establish suitability for every product format.
| Product format | Critical qualification points |
| Capsules | Bulk density, flow, particle size, moisture and fill-weight variation |
| Tablets | Compressibility, hardness, friability, sticking and disintegration |
| Powder blends | PSD matching, segregation, taste and blend uniformity |
| Sachets | Flow, dusting, reconstitution and humidity performance |
| Beverage powders | Dissolution, pH, clarity, taste and storage stability |
| Gummies or RTDs | Heat exposure, water activity, pH and matrix compatibility |
| Effervescent products | Moisture protection, ionic balance and dissolution |
Solid dosage forms and powder blends
Capsule projects should evaluate bulk density, tapped density, powder flow and achievable fill weight. A lower-density batch may require a larger capsule even when the chemical assay is unchanged.
Tablet performance depends on the complete excipient system and compression process. Pilot trials should evaluate hardness, friability, ejection, sticking, capping and disintegration instead of assuming that a water-soluble ingredient will compress effectively.
In powder blends, differences in particle size and density can cause segregation during mixing, transport and hopper feeding. Compatibility should be tested with sweeteners, acids, minerals, proteins, electrolytes and other amino acids used in the final formula.
Beverage and moisture-sensitive formats
Water solubility supports beverage-powder development, but dissolution time can vary with particle size, concentration, temperature, mixing speed and co-ingredients.
Beverage trials should assess:
- finished pH;
- solution clarity;
- dissolution time;
- taste and aftertaste;
- flavor masking;
- sediment or agglomeration;
- storage stability.
The hydrochloride form can contribute acidity and chloride load, so the finished formula must be tested rather than evaluated from the raw ingredient alone.
Gummies, RTD beverages and effervescent products require additional review of heat exposure, pH, water activity, packaging and storage. Essencefield’s product guidance recommends application-specific testing for these formats rather than assuming direct transfer from dry capsule or powder applications.
Chemical purity, flavor-use evaluation, certification status and published research do not independently establish finished-product suitability. The finished-product company remains responsible for the selected grade, use level, formulation validation, labeling and target-market compliance.
Scientific and Regulatory Context
Ornithine is a non-proteinogenic amino acid involved in the urea cycle and nitrogen metabolism. This established biological role provides the rationale for research into fatigue, stress and sleep-related outcomes.
A 2008 study investigated L-ornithine supplementation and physical-fatigue-related measurements in healthy volunteers. A 2014 randomized controlled trial examined stress markers, mood and sleep quality in healthy workers. The findings provide research context but do not establish guaranteed effects for every dose, population, finished product or chemical form. (2008 PubMed study; 2014 PubMed study)
Evidence involving L-ornithine L-aspartate or another ornithine derivative should not be transferred directly to L-Ornithine Hydrochloride Powder without confirming chemical form and dose equivalence.
For U.S. dietary supplements, the FDA dietary supplement CGMP guidance places responsibility on manufacturers to establish and verify appropriate specifications and quality-control procedures.
The JECFA entry evaluates L-ornithine monochlorohydrate within a flavoring context. It should not be presented as blanket authorization for unrestricted food, supplement or pharmaceutical use.
Essencefield Quality and Supply Support
Essencefield’s ingredient sourcing service supports specification matching, document review, sample evaluation, testing coordination, second-source planning and bulk supply preparation.
Depending on the confirmed source and project, the available package may include:
- current product specification;
- representative or lot-specific COA;
- TDS and SDS;
- sample or pilot quantity;
- allergen and GMO statements;
- country-of-origin information;
- relevant facility- or product-specific certificates;
- coordinated third-party testing.
Certification scope and document availability should correspond to the actual product, manufacturing facility and production source.
RFQ Checklist for Bulk Sourcing
For an accurate technical review and quotation, provide:
- intended application and dosage format;
- destination country or region;
- target assay and reporting basis;
- particle-size requirement;
- elemental-contaminant limits;
- microbiological limits;
- initial quantity and annual forecast;
- sample and packaging requirements;
- required technical or certification documents;
- target delivery date and preferred Incoterm.
Current commercial options are summarized in the procurement table above. Availability remains subject to the selected specification, current stock and document requirements.
Request Specifications, Samples or a Bulk Quote
Send the intended application, target specification, order quantity, destination market, packaging preference and document requirements through the Essencefield contact page.
The project form accepts the dosage format, estimated quantity, packaging needs, timeline and supporting files such as an existing specification or formula. This allows the technical and commercial team to review available grades, samples, testing requirements and bulk-supply terms.

















