Monopotassium phosphate powder is a water-soluble mineral salt used for buffering, pH adjustment, potassium and phosphate contribution, and fermentation support. It is commonly evaluated for beverage powders, electrolyte blends, mineral premixes and other food or nutrition formulations.
Also known as MKP, potassium dihydrogen phosphate or potassium phosphate monobasic, it has the chemical formula KH₂PO₄, CAS number 7778-77-0 and a molecular weight of approximately 136.09 g/mol.
For B2B buyers, the ingredient name and headline purity are only starting points. Grade, assay basis, pH test method, moisture, insoluble matter, particle size, elemental impurities and batch documentation can all determine whether a product is suitable for commercial manufacturing.
Essencefield’s Monopotassium Phosphate Powder product page provides current product, document, sample and bulk-supply information for formulation and supplier-qualification projects.
Product Identity and Key Properties
The Joint FAO/WHO Expert Committee on Food Additives identifies potassium dihydrogen phosphate as INS 340(i). Its monograph describes the ingredient as an odorless, white crystalline or granular powder that is freely soluble in water and may function as a buffer, neutralizing agent, sequestrant and yeast food.
| Property | Reference information |
|---|---|
| Chemical name | Potassium dihydrogen phosphate |
| Common names | Monopotassium phosphate, MKP, potassium phosphate monobasic |
| Formula | KH₂PO₄ |
| CAS number | 7778-77-0 |
| Molecular weight | Approximately 136.09 g/mol |
| Food additive identity | INS 340(i), E340(i) |
| Appearance | White crystalline or fine crystal powder |
| Solubility | Freely soluble in water |
| Solution profile | Acidic monobasic phosphate |
| Main functions | Buffering, pH adjustment, mineral contribution and fermentation support |
Monopotassium phosphate belongs to the wider potassium phosphate family, but it should not be confused with dipotassium or tripotassium phosphate. Each salt has a different potassium-to-phosphate ratio and produces different solution behavior.
MKP generally provides a more acidic phosphate profile than dipotassium phosphate. The appropriate form depends on the desired pH, mineral contribution, process conditions and finished-product specification.
Selecting the Correct Monopotassium Phosphate Grade
A high assay does not by itself confirm food- or nutrition-grade suitability.
Materials with the same CAS number and formula may differ in:
- Applicable quality standard
- Impurity limits
- Analytical methods
- Particle-size distribution
- Manufacturing source
- Packaging controls
- Traceability
- Certification scope
| Grade direction | Typical application | Main approval criteria |
|---|---|---|
| Food or nutrition grade | Beverages, electrolyte products and nutritional formulations | Assay, pH, contaminants, solubility and regulatory documents |
| Application-qualified grade | Premixes, capsules, tablets and sachets | Chemical specification plus particle size, density and flowability |
| Technical grade | Industrial or process formulations | Process-specific purity and impurity requirements |
| Fertilizer grade | Agricultural nutrient systems | Nutrient guarantee, insolubles, chloride and agricultural suitability |
Food- and nutrition-grade material
JECFA provides a useful reference specification for potassium dihydrogen phosphate. Its criteria include an assay of at least 98% after drying, a pH of 4.2–4.7 for a 1-in-100 solution, loss on drying of no more than 2%, and water-insoluble substances of no more than 0.2%. It also provides reference limits for fluoride, arsenic and lead.
These figures should not automatically be copied into every commercial specification. The required limits may differ according to:
- Destination market
- Finished-product category
- Customer quality standard
- Use level
- Internal risk assessment
- Applicable regulatory framework
The US FDA’s food-substance inventory associates potassium phosphate monobasic with technical effects including malting or fermentation assistance, nutrient supplementation, pH control, and stabilization or thickening. The intended food use and applicable conditions still require product-specific regulatory review.
European buyers should also verify the current requirements applying to E340 potassium phosphates and the intended food category rather than relying solely on a supplier’s general “food grade” statement.
Fertilizer grade is not interchangeable with food grade
Fertilizer-grade MKP is commonly sold under a 0-52-34 nutrient declaration. That analysis is relevant to agricultural nutrient content but does not demonstrate food-additive compliance.
A fertilizer specification may focus on P₂O₅, K₂O, chloride, sodium and irrigation compatibility. A food or nutrition specification instead requires appropriate contaminant controls, production documentation and destination-market suitability.
Food manufacturers should never approve fertilizer-grade material based only on high assay or water solubility.
Specifications Buyers Should Review
A technically useful specification distinguishes guaranteed limits from typical or reference values.
| Data type | Meaning |
|---|---|
| Contract specification | Limits each commercial batch must meet |
| Typical value | A normal but non-guaranteed production result |
| Batch COA result | The measured value for a specific lot |
| Regulatory reference | A criterion published by an authority |
| Application target | A limit established through formulation testing |
Typical values help characterize a product but should not replace measurable contractual requirements.
Assay and reporting basis
Assay shows the measured KH₂PO₄ content. Buyers should verify whether the value is reported:
- As received
- After drying
- On an anhydrous basis
- By titration
- Through phosphorus analysis
- By another validated method
A dried-basis result removes the effect of measured moisture. Two products can therefore report similar dried-basis purity while delivering different quantities of active material per kilogram as received.
The analytical method should appear in the specification or an incorporated standard. A result cannot be compared reliably when the supplier and buyer use materially different methods or calculation bases.
pH and test conditions
The pH of MKP is relevant to buffering, beverage formulation, fermentation and mineral compatibility.
However, a pH value is meaningful only when the method specifies:
- Solution concentration
- Water quality
- Temperature
- Mixing or equilibration time
- Instrument procedure
JECFA’s pH range applies to a defined 1-in-100 solution. It should not be compared directly with a supplier result measured using another concentration.
The final formulation pH also depends on other acids, bases, minerals, sweeteners and processing conditions. Ingredient-level pH is therefore a qualification parameter rather than a prediction of finished-product pH.
Moisture and loss on drying
Moisture influences active content and powder handling.
Excess moisture can contribute to:
- Caking
- Reduced flowability
- Poor hopper discharge
- Filling variation
- Uneven blending
- Lower as-received active content
The test temperature and drying duration should be defined because different loss-on-drying methods can produce different results.
Moisture should also be considered with packaging integrity and warehouse conditions. A compliant batch may still develop handling problems after prolonged exposure to humid air.
Water-insoluble matter
Water-insoluble matter is especially important for beverage powders, clear liquids, electrolyte products and filtered processing systems.
Elevated insolubles may cause:
- Haze
- Sediment
- Filter loading
- Deposits in tanks or pipelines
- Visible particles
- Inconsistent dosing
A material can meet its chemical assay while delivering unacceptable clarity in the finished product.
For liquid applications, test the qualification sample using the intended process water, temperature, concentration and order of addition. Hardness and other dissolved minerals may create precipitation that is not visible in a distilled-water solubility test.
Elemental and process-relevant impurities
Depending on grade and application, the specification may control:
- Lead
- Arsenic
- Cadmium
- Mercury
- Fluoride
- Iron
- Sodium
- Chloride
- Sulfate
A result reported as “not detected” is meaningful only when the analytical detection limit is below the agreed acceptance criterion.
Iron can be relevant to transparent or color-sensitive beverages. Sodium may require reporting in electrolyte formulas with defined label targets. Chloride, sulfate and fluoride may be controlled according to a recognized standard or customer specification.
Particle size and bulk density
Chemical purity does not predict powder-processing performance.
Particle size can affect:
- Dissolution speed
- Dust generation
- Blend uniformity
- Segregation
- Hopper discharge
- Filling accuracy
- Tablet or capsule processing
Very fine material may dissolve rapidly but generate more dust or flow poorly. Coarser crystals may handle more consistently but require longer mixing or dissolution.
Bulk density influences volumetric feeding, package volume, hopper capacity and unit-dose filling. Buyers should qualify the physical grade intended for routine production rather than testing one sample and purchasing another particle profile.
Essencefield’s Minerals Ingredients portfolio allows buyers to compare mineral ingredients by chemical form, elemental contribution and intended application.
Food and Nutrition Applications
The suitability of monopotassium phosphate powder should be confirmed in the complete formula. Assay and water solubility alone cannot predict taste, clarity, stability or processing performance.
Beverage and electrolyte systems
In beverage powders and electrolyte blends, MKP may provide potassium and phosphate while contributing an acidic phosphate profile.
Development trials should evaluate:
- Dissolution time
- Equilibrium pH
- Mineral taste
- Solution clarity
- Sediment
- Interaction with acids and sweeteners
- Stability after reconstitution
- Moisture sensitivity of the dry blend
The commercial use level should be calculated from the required mineral contribution, pH target, finished serving and applicable labeling requirements.
A clear solution immediately after mixing does not guarantee shelf-life stability. RTD and concentrated liquid systems should be assessed after heat processing, cooling, filtration and storage.
Dry premixes and solid dosage forms
In mineral premixes, capsules, tablets and sachets, physical properties can be as important as chemical purity.
Important variables include:
- Particle-size compatibility
- Bulk-density differences
- Flowability
- Blend sequence
- Segregation risk
- Fill-weight consistency
- Moisture exposure
- Packaging barrier
Large differences in particle size or density can cause ingredients to separate during transport, hopper discharge or filling. Low-dose ingredients are especially vulnerable to poor distribution.
Essencefield’s guide to powder supplement mixing uniformity explains how particle size, density, humidity, static charge and sampling affect consistency in commercial powder blends.
Fermentation and process formulations
MKP may also be evaluated as a potassium and phosphate source in fermentation systems. JECFA identifies yeast food as one of its functions, while the FDA inventory includes malting or fermenting aid among its technical effects.
Process qualification should monitor pH behavior, nutrient balance, microbial growth, yield and downstream composition. The selected grade must match the regulatory status and quality requirements of the final output.
Mineral Compatibility and Formulation Testing
Phosphate can interact with calcium, magnesium, iron, zinc and other multivalent ions. Under unfavorable conditions, these interactions may produce haze, sediment or insoluble salts.
The risk depends on:
- Mineral concentration
- Order of addition
- Water quality
- Temperature
- Equilibrium pH
- Other acids and salts
- Storage time
A practical development approach is to dissolve MKP fully before adding concentrated sources of other minerals. Record pH and appearance after each addition so incomplete dissolution can be distinguished from precipitation.
Compatibility should be tested after the complete formula reaches its target pH and concentration. Observations should continue through processing and shelf-life studies because precipitation can develop gradually rather than during initial mixing.
Supplier Documentation and Batch Approval
Supplier approval should connect the written specification, analytical methods, qualification sample and commercial batch.
Required documents
A project-specific document package may include:
- Signed specification
- Batch-specific COA
- Technical Data Sheet
- Safety Data Sheet
- Country-of-origin statement
- Allergen statement
- GMO statement
- Manufacturing declaration
- Packaging specification
- Relevant facility or product certificates
Document availability and certification scope can vary by manufacturing source. Buyers should verify the certificate holder, facility address, product scope and validity period.
Essencefield’s Testing and Certifications resource explains how specifications, COA, TDS, SDS, third-party laboratory reports and facility-specific certification documents are reviewed for ingredient and supplement projects.
COA review
A batch COA should identify:
| COA field | Buyer review |
|---|---|
| Product and grade | Match the purchase order and approved specification |
| Batch number | Match labels and shipping documents |
| Specification limit | Confirm the contractual acceptance criterion |
| Actual result | Verify that the batch meets the limit |
| Unit | Confirm concentration and reporting basis |
| Test method | Check method suitability |
| Approval status | Confirm authorized release |
| Dates | Review manufacturing, release or retest information |
Pay particular attention to:
- Assay basis
- pH solution concentration
- Loss-on-drying method
- Detection limits for elemental impurities
- Particle-size method
- Parameters omitted from the COA
The COA should be reviewed against the approved specification rather than treated as a standalone quality certificate.
Sample and first-lot comparison
A representative sample should be tested before bulk approval, but sample success does not automatically qualify future batches.
The first commercial lot should be compared with the approved sample for:
- Appearance
- Assay
- pH
- Moisture
- Particle size
- Bulk density
- Dissolution
- Solution clarity
- Finished-product performance
Any customized particle profile, impurity limit or testing requirement should be written into the commercial specification.
Essencefield’s raw-material quality process covers supplier qualification, specification approval, COA review, incoming inspection and batch traceability.
Commercial and RFQ Requirements
Packaging, MOQ, lead time and logistics should be confirmed for the exact grade and destination rather than assumed from another potassium phosphate product.
The RFQ should include:
- Intended application and dosage format
- Required grade and destination market
- Minimum assay and calculation basis
- Required pH range and test conditions
- Maximum moisture and insoluble matter
- Elemental and process-relevant impurity limits
- Particle-size and bulk-density requirements
- Trial quantity and annual forecast
- Packaging and pallet requirements
- Required documents and certifications
- Third-party testing requirements
- Delivery destination, Incoterm and timeline
Ask suppliers to identify every deviation from the requested specification. General descriptions such as “high purity,” “premium grade” or “food grade” should not replace measurable acceptance criteria.
For projects comparing multiple manufacturers or requiring a second source, Essencefield’s ingredient sourcing support can assist with source, specification, documentation and supply-option review.
Request Monopotassium Phosphate Specifications
Monopotassium phosphate powder should be approved according to its complete quality and application profile—not its formula, CAS number or assay alone.
Before commercial purchase, verify:
- Correct grade and market suitability
- Assay basis and analytical method
- pH and test concentration
- Moisture and insoluble matter
- Elemental impurities
- Particle size and bulk density
- Formulation compatibility
- Batch-specific documentation
- Packaging and commercial terms
- Source traceability
Use the Essencefield contact page to request the current specification, representative COA, qualification sample, packaging details and a project-specific bulk quotation. Provide the intended application, destination market, target limits, estimated volume and required documents for a more accurate technical and commercial review.

















