N-acetyl tyrosine powder, commonly called NALT powder, is an acetylated derivative of L-tyrosine used in capsules, tablets, premixes, stick packs, powdered supplements, and selected beverage systems.
A stated assay of 98% or 99% is not enough to approve a commercial ingredient. Buyers must also evaluate chemical identity, free L-tyrosine, related substances, moisture, physical properties, contaminant controls, batch consistency, technical documentation, and performance in the intended formula.
To evaluate an N-acetyl tyrosine powder supplier, verify identity, HPLC assay, free L-tyrosine, related substances, moisture, and lot-specific physical properties. Test a qualification sample in the finished formula, compare it with the commercial lot, and confirm traceability, change control, documentation, and total delivered cost.
Current commercial specifications and sampling information are available on the Essencefield N-acetyl tyrosine powder product page.
NALT Identity and Selection Basics
N-acetyl-L-tyrosine is the L-form of tyrosine modified with an acetyl group. The NIH PubChem compound record lists its molecular formula as C11H13NO4 and its molecular weight as approximately 223.22 g/mol.
| Identity item | Reference information |
|---|---|
| Commercial name | N-Acetyl-L-Tyrosine |
| Common abbreviation | NALT |
| CAS number | 537-55-3 |
| Molecular formula | C11H13NO4 |
| Molecular weight | Approximately 223.22 g/mol |
| Typical appearance | White to off-white crystalline powder |
The FDA substance record for acetyl L-tyrosine confirms recognized names and chemical identity. The presence of an FDA substance identifier does not mean that every ingredient grade, application, label claim, or finished product has received regulatory approval.
Buyers must assess suitability according to the destination country, finished-product category, intended use, ingredient documentation, and applicable regulatory requirements.
NALT vs. L-Tyrosine
NALT and free L-tyrosine are chemically related but should not be treated as direct gram-for-gram substitutes.
| Selection factor | NALT powder | L-tyrosine powder |
|---|---|---|
| Chemical form | Acetylated derivative | Free amino acid |
| Molecular weight | Approximately 223.22 g/mol | Approximately 181.19 g/mol |
| Formulation consideration | Often assessed when water compatibility matters | Commonly used in capsules, tablets, and dry powders |
| Evidence relevance | Evidence must match the exact form and administration route | More studies directly evaluate free L-tyrosine |
| Main selection risk | Assuming water behavior proves superior bioavailability | Underestimating solubility or sedimentation constraints |
Improved water compatibility does not automatically establish improved oral absorption. Solubility, absorption, deacetylation, systemic availability, and physiological performance are separate properties.
A human intravenous study indexed by PubMed reported substantial urinary excretion of unchanged N-acetyl-L-tyrosine. Because the study used intravenous administration, it should not be treated as direct evidence for every oral supplement. It does, however, support cautious interpretation of broad “superior bioavailability” claims.
The commercial choice between NALT and L-tyrosine should be based on:
- Dosage form
- Finished-product evidence
- Formula behavior
- Label calculations
- Destination-market requirements
- Ingredient and processing cost
For a separate review of the free amino acid, see Essencefield’s L-tyrosine powder selection guide.
How to Review a NALT COA
A certificate of analysis should demonstrate whether a specific batch meets the approved purchasing specification. It should not be a generic document that repeats only the supplier’s marketing claims.
The FDA’s dietary supplement CGMP compliance guide addresses component specifications, representative sampling, supplier qualification, quality-control review, and lot traceability.
Core COA Evaluation Table
| COA parameter | Suitable evidence | Buyer red flag |
|---|---|---|
| Identity | Specific analytical method compared with an appropriate standard | Identification based only on appearance |
| Assay and reporting basis | Numerical HPLC result stated on a dry or as-is basis | “Conforms” with no result or calculation basis |
| Free L-tyrosine | Individual result or agreed acceptance limit | Hidden within a general purity claim |
| Related substances | Individual and total limits where relevant | No impurity information |
| Moisture | Numerical result with a defined method | Described only as “low” |
| Particle size and density | Lot-specific data when required by the application | One generic mesh statement for every lot |
| Contaminants and microbiology | Defined limits and batch results | General compliance statement without details |
Assay and Reporting Basis
Identity confirms that the received material is N-acetyl-L-tyrosine. Assay measures how much of the specified analyte is present under the stated test method.
The COA should identify:
- Analytical method
- Acceptance range
- Actual batch result
- Reporting basis
- Reference standard or method reference
A dry-basis result corrects for measured moisture. An as-is result represents the material in its received condition. Purchasing specifications, formulation calculations, and batch-release decisions should use a consistent basis.
For example, two suppliers may both report 98% assay, but the figures are not directly comparable when one is calculated on a dry basis and the other is reported as-is.
Free L-Tyrosine and Related Substances
The headline assay does not explain the identity of the remaining material.
Depending on the production route and agreed specification, impurity controls may cover:
- Free or unreacted L-tyrosine
- Known process-related compounds
- Individual unknown impurities
- Total related substances
Free L-tyrosine can act as a process-consistency indicator. Changes may reflect variation in reaction completion, purification, crystallization, drying, or storage.
The buyer should determine whether impurities are individually reported, included only in a total result, or not measured. A supplier advertising “98% purity” should be able to explain how the remaining fraction is characterized and controlled.
Moisture, Particle Size, and Density
Chemical compliance does not predict how a powder will flow, blend, fill, disperse, or resist caking.
Application-specific requirements may include:
- Loss on drying or water content
- Water activity
- Sieve result
- D10, D50, and D90 particle-size values
- Bulk density
- Tapped density
- Flowability
A mesh result indicates whether particles pass through a particular sieve. It does not describe the full particle-size distribution.
Bulk density affects how much powder fits into a capsule, blender, hopper, or package. Particle-size and density differences can also increase segregation when NALT is mixed with minerals, flavors, sweeteners, caffeine granules, or other amino acids.
These parameters are not inherently better when higher or lower. They must match the intended dosage form and production equipment.
COA Red Flags
A batch-specific COA requires further investigation when it contains:
- No identifiable batch number
- No numerical assay result
- No analytical method or method reference
- An undefined reporting basis
- No impurity information
- Marketing claims that conflict with the COA
A generic specification can support early supplier screening, but it does not prove the quality of the commercial lot offered for shipment.
Test the Commercial Grade in the Finished Formula
A raw material can pass its chemical specification and still fail during manufacturing. The qualification sample should therefore be tested in the complete formula under representative processing and use conditions.
| Dosage form | Priority evaluation | Main production risk |
|---|---|---|
| Capsules | Density, flow, fill weight, uniformity | Variable capsule weight or insufficient capacity |
| Tablets | Compression, hardness, friability, disintegration | Sticking, weak tablets, or poor release |
| Premixes | Particle alignment and blend uniformity | Uneven active distribution |
| Stick packs | Flow, caking, and moisture behavior | Filling variation or storage hardening |
| Beverage powders | Wetting, dispersion, pH, haze, and sediment | Grit, clouding, or precipitation |
Capsules, Tablets, and Dry Blends
For capsules, bulk density and flow can affect shell size, hopper performance, and fill-weight consistency.
Tablet development requires additional evaluation of compressibility, lubricant compatibility, sticking, hardness, friability, and disintegration. A material approved for capsule filling should not automatically be approved for direct compression.
In premixes and stick packs, particle-size or density mismatch can cause segregation. Low-inclusion NALT may require geometric dilution or a preblend before entering the main mixer.
Blend uniformity should be assessed at multiple discharge points, not from only one convenient sample.
Beverage Systems
A supplier statement that NALT is “water-soluble” is not a complete beverage specification.
A representative bench test should define:
- Ingredient concentration
- Water temperature and hardness
- Mixing method and duration
- Initial and final pH
- Presence of acids, minerals, sweeteners, caffeine, or flavors
- Observation time
- Acceptance criteria
The test should distinguish initial wetting from complete dissolution and record haze, sediment, foam, color, odor, and consumer-perceived grit.
A powder that performs acceptably in plain water may behave differently in a formula containing citric acid, calcium, magnesium, flavor systems, or other active ingredients.
Supplier Qualification and Testing Responsibility
The organization issuing the quotation may be the original manufacturer, an authorized distributor, an exporter, a trader, or a contract packer.
The buyer should establish which party controls:
- Manufacturing
- Analytical testing
- Batch release
- Storage
- Documentation
- Complaint handling
- Change notification
| Document or control | Procurement purpose |
|---|---|
| Approved specification | Defines agreed tests and acceptance limits |
| Batch-specific COA | Shows results for the offered commercial lot |
| TDS and SDS | Support technical, handling, and safety review |
| Origin and compliance statements | Support customer and destination-market requirements |
| Traceability records | Connect the batch with its source and supply history |
| Change-control procedure | Defines when material changes must be reported |
Essencefield’s raw-material quality process describes supplier qualification, specification confirmation, COA verification, incoming inspection, traceability, and batch documentation as part of ingredient review.
The supplier should also explain which tests are:
- Performed by the original manufacturer
- Conducted internally
- Outsourced to an independent laboratory
- Verified periodically rather than on every commercial lot
The phrase “third-party tested” has limited value unless the buyer knows which sample was tested, which methods were used, and which acceptance criteria applied.
Essencefield’s testing and certification support includes coordination of COAs, technical documents, third-party reports, and project-specific testing requirements. Required methods, limits, and report formats should be agreed before testing begins.
Sample-to-Lot Consistency
A qualification sample is useful only when it represents the commercial grade.
The approved sample and first commercial lot should be compared for:
- Assay
- Free L-tyrosine
- Related substances
- Moisture
- Particle-size distribution
- Bulk density
- Color and odor
- Finished-formula performance
The purchasing agreement should also define whether changes to the manufacturing site, production process, analytical method, specification, particle grade, or packaging require customer notification.
A material change that could influence production performance may require analytical or formulation requalification.
Total Procurement Cost
The lowest quoted price per kilogram may not produce the lowest finished-product cost.
A meaningful comparison should consider delivered price, assay basis, freight, customs, laboratory testing, manufacturing yield, rejection risk, lead time, safety stock, MOQ, and payment terms.
A basic assay-adjusted comparison is:
Assay-adjusted cost = delivered price per kilogram ÷ assay fraction
For example, a hypothetical NALT powder delivered at $50/kg with 98% assay has an assay-adjusted raw-material cost of approximately $51.02/kg of measured NALT.
This calculation excludes testing, process loss, inventory, and quality failures. It should therefore support—not replace—a broader total-cost review.
NALT Supplier Evaluation Scorecard
| Evaluation category | Suggested weighting |
|---|---|
| Identity and impurity control | 25% |
| Physical and formulation performance | 20% |
| Quality system and traceability | 20% |
| Sample-to-lot consistency | 15% |
| Documentation and technical support | 10% |
| Commercial terms and lead time | 10% |
Identity failure, unacceptable contamination, falsified documentation, or missing traceability should be treated as disqualifying conditions. They should not be offset by a lower price.
Essencefield NALT Supply Support
Essencefield publishes a typical minimum 98.0% HPLC dry-basis assay for its N-acetyl tyrosine powder and supports project-specific review of impurities, moisture, physical properties, technical documentation, samples, quantities, and delivery requirements.
Buyers can request a current specification, recent batch-specific COA, qualification sample, TDS, SDS, and commercial quotation through the Essencefield NALT product page.
Projects requiring more than raw-material supply can also use Essencefield’s supplement manufacturing services for ingredient sourcing, formulation, pilot scale-up, contract production, private-label manufacturing, and packaging coordination.
Final specifications, test methods, documents, quantities, packaging, and service scope should be confirmed in the approved project documents.
Final Procurement Recommendation
N-acetyl tyrosine powder should be approved against an application-specific purchasing specification.
A reliable process should:
- Define the dosage form, destination market, and technical requirements.
- Review a batch-specific COA and supporting test methods.
- Test the qualification sample in the finished formula.
- Compare it with the commercial lot and confirm traceability, change control, supply terms, and total cost.
The strongest NALT supplier is not necessarily the company offering the highest advertised purity or lowest price. It is the supplier that can repeatedly deliver the agreed chemical identity, impurity control, physical performance, documentation, and commercial support required by the finished product.