

Ammonium Sulfate Powder is a highly water-soluble inorganic salt typically supplied at ≥99.0% for fermentation media, nutrient feed and stock solutions, multi-salt premixes, process chemistry, and pilot evaluation. Fine powder, crystalline, and granular forms can be selected according to dissolution speed, dust tolerance, and production handling requirements. Essencefield supports bulk buyers with specification review, samples, batch documentation, custom testing, moisture-resistant packing, and repeat supply coordination.
| Item | Typical Supply Information |
|---|---|
| Product Name | Ammonium Sulfate Powder |
| Chemical Name | Ammonium sulfate |
| CAS Number | 7783-20-2 |
| Molecular Formula | (NH₄)₂SO₄ |
| Molecular Weight | 132.14 g/mol |
| Standard Specification | Typically ≥99.0% |
| Grade | Technical / industrial process grade |
| Appearance / Form | White fine powder, crystalline material, or granules |
| Particle Size | Typically 20–80 mesh; custom ranges by specification |
| Solubility | Highly soluble in water |
| Solution pH | Slightly acidic at a defined test concentration |
| Moisture | Controlled according to the approved specification |
| Insoluble Matter | Controlled for filtration and liquid-dosing applications |
| Chloride | Standard or custom specification |
| Iron | Standard or custom specification |
| Standard Packing | Typically 25 kg |
| Shelf Life | Typically 36 months in unopened, dry storage |
| Country of Origin | China, unless otherwise confirmed |
| Supply Option | Intended Use |
| Fine Powder | Faster dissolution in media and stock solutions |
| Crystalline / Granular Form | Lower-dust charging and bulk handling |
| Custom Specification | Defined particle size, chloride, iron, or insoluble-matter targets |
Ammonium sulfate should be qualified against the intended process rather than assay alone. Moisture can affect caking, open-bag flow, weighing consistency, and automated feeding. Insoluble matter may increase residue in liquid tanks, filters, and dosing systems. Chloride can require tighter control where equipment metallurgy or corrosion monitoring is sensitive, while iron may influence trace-element background, color, or biological performance.
Particle form also affects processing. Fine powder generally dissolves faster but may generate more airborne dust. Crystalline or granular material may improve charging and handling but require longer mixing. Solution pH and clarity should be assessed at the intended concentration, temperature, and water quality because preparation conditions influence the result. Commercial qualification should compare representative batches, align supplier and incoming-QC methods, verify packaging integrity, and clearly distinguish routine release parameters from optional project testing.
| Test Item | Typical Limit / Control Basis |
| Identification | Conforms to ammonium and sulfate identification |
| Assay as (NH₄)₂SO₄ | Typically ≥99.0% |
| Appearance | White powder, crystalline material, or granules |
| Moisture / Loss on Drying | According to the approved specification |
| Solution pH | Defined at an agreed solution concentration |
| Insoluble Matter | According to the approved specification |
| Particle Size | Typically 20–80 mesh or agreed range |
| Chloride | Standard or custom limit |
| Iron | Standard or custom limit |
| Heavy Metals | According to the confirmed grade and destination requirements |
Optional testing may include nitrogen content, solution clarity, bulk density, residue on ignition, extended elemental analysis, custom particle distribution, or third-party verification.
Routine release should focus on identity, assay, appearance, moisture, solution pH, insoluble matter, particle size, chloride, iron, packaging condition, and batch traceability. A buyer-ready COA should show the product name, batch reference, specification limits, actual results, and applicable test methods where available.
Supplier and buyer methods should be aligned before commercial approval because sample preparation, solution concentration, drying conditions, and analytical instruments may affect reported results. For example, pH values are only comparable when the same solution concentration and water conditions are used. Moisture and insoluble-matter results may also vary with drying time, filtration method, and sample handling.
Final acceptance criteria should be recorded in the approved specification rather than remaining only in quotations or email discussions. Buyers with sensitive equipment, narrow impurity limits, concentrated stock solutions, or long-term supply programs should review representative batches before full commercial qualification.
| Application | Practical Role |
| Fermentation and Nutrient Media | Inorganic nitrogen contribution in validated microbial processes |
| Feed and Stock Solutions | Preparation of aqueous feeds or liquid dosing solutions |
| Multi-Salt Premixes | Dry blending with compatible mineral and process salts |
| Process Chemistry | Controlled ammonium and sulfate contribution |
| R&D and Pilot Evaluation | Screening before commercial specification approval |
| Protein Precipitation Screening | Process evaluation after confirming grade, impurities, and solution suitability |
These ranges are starting points for laboratory or pilot evaluation rather than universal production dosages. Performance depends on water quality, temperature, pH, ionic strength, concentration, particle form, mixing energy, filtration design, addition order, holding time, and companion salts.
Fermentation trials should monitor growth, productivity, nitrogen utilization, pH drift, and osmotic load before scale-up. Stock-solution studies should record dissolution time, solution clarity, filtration behavior, crystallization, and storage stability. Separate concentrates may be appropriate when phosphate, magnesium, or trace-mineral components create precipitation risk.
For dry premixes, particle-size and density differences should be evaluated under blending, filling, transport, and vibration conditions. Where several mineral salts must be managed under one specification, a custom mineral premix may reduce customer-side weighing and staging. Final approval should remain based on the complete process, selected grade, receiving specification, and actual production results.
| Application | Practical Role |
| Fermentation and Nutrient Media | Inorganic nitrogen contribution in validated microbial processes |
| Feed and Stock Solutions | Preparation of aqueous feeds or liquid dosing solutions |
| Multi-Salt Premixes | Dry blending with compatible mineral and process salts |
| Process Chemistry | Controlled ammonium and sulfate contribution |
| R&D and Pilot Evaluation | Screening before commercial specification approval |
| Protein Precipitation Screening | Process evaluation after confirming grade, impurities, and solution suitability |
These ranges are starting points for laboratory or pilot evaluation rather than universal production dosages. Performance depends on water quality, temperature, pH, ionic strength, concentration, particle form, mixing energy, filtration design, addition order, holding time, and companion salts.
Fermentation trials should monitor growth, productivity, nitrogen utilization, pH drift, and osmotic load before scale-up. Stock-solution studies should record dissolution time, solution clarity, filtration behavior, crystallization, and storage stability. Separate concentrates may be appropriate when phosphate, magnesium, or trace-mineral components create precipitation risk.
For dry premixes, particle-size and density differences should be evaluated under blending, filling, transport, and vibration conditions. Where several mineral salts must be managed under one specification, a custom mineral premix may reduce customer-side weighing and staging. Final approval should remain based on the complete process, selected grade, receiving specification, and actual production results.
| Item | Supply Information |
| Standard MOQ | Typically 25 kg |
| Samples | Available for specification, dissolution, particle-size, filtration, and document review |
| Standard Lead Time | Typically 7–15 working days |
| Standard Documents | Batch COA, TDS, SDS, specification sheet, and origin statement |
| Custom Testing | Impurity, elemental, physical, particle-size, or third-party testing by agreement |
| Custom Packing | Reviewed according to order quantity and shipping route |
| Bulk Supply | Standard packing and larger repeat-order programs supported |
For an accurate quotation, provide:
Buyers replacing an existing source may submit a specification, COA, or comparison sample through the ingredient sourcing service for preliminary matching, sample coordination, and document review.
Share your target specification, application, quantity and document needs. We will help confirm suitable options, COA/TDS/SDS support and bulk supply details.
Explore related ingredients for formula comparison, complementary applications and alternative sourcing options across food, beverage, supplement and wellness projects.