Yellow-orange 98% Coenzyme Q10 ubiquinone crystalline powder

Coenzyme Q10 Powder

Coenzyme Q10 Powder, also called CoQ10 or ubiquinone-10, is a yellow to orange-yellow crystalline ingredient commonly specified at ≥98.0% by HPLC. Practically insoluble in water, it is suited to softgels, capsules, tablets, oil suspensions, and qualified premixes. Essencefield supports specification review, samples, batch documentation, protective packing, and international bulk supply for supplement brands and contract manufacturers.

Top Key Specs

ItemB2B Specification Details
Product NameCoenzyme Q10 Powder
Common NamesCoQ10, Ubiquinone-10, Ubidecarenone
Chemical Name2,3-Dimethoxy-5-methyl-6-decaprenyl-1,4-benzoquinone
CAS No.303-98-0
Molecular FormulaC59H90O4
Molecular Weight863.34 g/mol
Commercial FormCrystalline ubiquinone powder
Common Specification≥98.0% Coenzyme Q10, subject to the approved specification
Analytical MethodHPLC
AppearanceYellow to orange-yellow crystalline powder
SolubilityPractically insoluble in water; suited to oil-phase or qualified delivery systems
Particle SizeSieve or D90 target confirmed according to filling, tableting, premixing, or granulation requirements
Loss on DryingTypically ≤0.5%, subject to the approved specification
Residue on IgnitionTypically ≤0.1%, subject to the approved specification
Shelf LifeTypically 24 months unopened under recommended storage conditions
StorageKeep sealed in a cool, dry, and light-protected area

This page covers crystalline ubiquinone, CAS 303-98-0. Dispersible, carrier-based, and microencapsulated CoQ10 require separate specifications because their active concentration and processing behavior differ.

Assay alone does not determine commercial performance. The approved specification should also define identity, related substances, optional isomer reporting, residual-solvent scope, particle-size distribution, moisture, packaging, and analytical methods. Crystal size and density can influence dusting, electrostatic behavior, blend uniformity, capsule filling, tablet compression, and oil-phase incorporation. Light, oxygen, excessive heat, and prolonged open-air handling may contribute to color or potency changes. Buyers should therefore compare each commercial lot with the approved sample and review assay, appearance, physical behavior, packaging condition, and supporting documentation together. For repeat orders, the specification, analytical method, reference sample, and packaging configuration should remain consistent wherever practical. This reduces the risk of receiving material that satisfies a basic potency requirement but performs differently during blending, encapsulation, compression, or finished-product stability testing.

Typical COA Limits

The following values are typical planning limits. Final acceptance criteria and analytical methods must be confirmed in the approved specification before sample qualification or commercial ordering.

Physical and Chemical Parameters

Test ItemTypical Limit or Reporting BasisMethod
AppearanceYellow to orange-yellow crystalline powderVisual
IdentificationConformsHPLC, IR, UV, or agreed method
Coenzyme Q10 AssayTypically ≥98.0%HPLC
Related SubstancesBuyer-defined limitHPLC
Isomer ProfileOptional reportingHPLC
Melting RangeAgreed rangeApproved method
Loss on DryingTypically ≤0.5%Gravimetric
Residue on IgnitionTypically ≤0.1%Gravimetric
Particle-Size DistributionApproved sieve or D90 targetSieve or laser diffraction
Bulk DensityReported when specifiedApproved method
Residual SolventsRoute-specific limitGC or agreed method
Foreign MatterNo visible foreign matterVisual

Heavy Metals

Test ItemTypical Limit
Lead (Pb)≤0.5 mg/kg or buyer-defined limit
Arsenic (As)≤0.5 mg/kg or buyer-defined limit
Cadmium (Cd)≤0.5 mg/kg or buyer-defined limit
Mercury (Hg)≤0.1 mg/kg or buyer-defined limit
Total Heavy MetalsAccording to the approved specification

Microbiological Limits

Test ItemTypical Limit
Total Plate Count≤1,000 cfu/g
Yeast and Mold≤100 cfu/g
Coliforms≤10 cfu/g
Escherichia coliNegative / 1 g
SalmonellaNegative / 25 g
Staphylococcus aureusNegative or buyer-defined limit

Optional Project Testing

  • Expanded impurity or isomer profile
  • Defined particle-size and density testing
  • Independent contaminant testing
  • Stability testing under an agreed protocol

Commercial lots should be released against the approved specification rather than a generic product description. The release package should identify the product, lot reference, test methods, acceptance limits, actual results, packaging configuration, and traceability records. Essencefield’s raw material quality process connects supplier qualification, specification approval, incoming inspection, COA review, material release, storage controls, and batch traceability. For formulation-sensitive projects, the commercial lot should also be compared with the approved trial material for application-relevant physical behavior. Optional development or stability tests should not be presented as routine COA items unless they are performed for every released lot. When additional impurity analysis, retained-sample comparison, third-party testing, or stability review is required, the test method, storage conditions, acceptance criteria, and reporting format should be agreed before ordering.

Features & Benefits

  • Defined High-Assay Ubiquinone: The commercial form is clearly identified as crystalline ubiquinone commonly specified at ≥98.0% by HPLC.
  • Lot-Specific Quality Review: Identity, assay, related substances, physical parameters, contaminant limits, and actual batch results support incoming-material approval.
  • Application-Matched Physical Properties: Particle size and density can be aligned with the selected dosage format and processing method.
  • Protective Packaging Options: Light-protective inner packing, reduced headspace, divided packs, or nitrogen flushing may be selected according to project requirements.
  • Traceable Documentation: COA, TDS, SDS, specifications, origin information, and available compliance statements can be reviewed through testing and certifications.
  • Sample and Repeat-Order Support: Samples, specification matching, packaging review, and repeat-order planning support commercial qualification.

Applications & Formulation Ideas

Application Guidance

ApplicationPractical Formulation Direction
Softgels and Oil SuspensionsEvaluate carrier oil, dissolution or suspension behavior, temperature, oxygen exposure, viscosity, settling, filtration, and fill uniformity
Hard CapsulesMatch particle size and density with excipients; use geometric premixing, granulation, or carrier adsorption where needed
TabletsAssess flowability, granulation, compression behavior, lubricant compatibility, color distribution, and content uniformity
Powder PremixesUse a suitable carrier and controlled dilution sequence to reduce hotspots, dusting, and segregation
Gummies and BarsEvaluate oil distribution, thermal exposure, color migration, sensory impact, oxidative stability, and active uniformity
Beverage and Emulsion SystemsUse a qualified dispersion, emulsion, carrier, or encapsulation system; crystalline CoQ10 should not be treated as directly water soluble

Crystalline ubiquinone is best suited to lipid-based, encapsulated, or technically qualified delivery systems. In softgel supplement manufacturing, the carrier oil, active loading, fill viscosity, particle size, settling behavior, oxidation protection, and shell compatibility should be evaluated together. Hard capsules and tablets require control of particle size, density, static behavior, and dilution sequence because relatively low active levels can increase segregation and content-uniformity risk. Water-based systems may require a carrier, emulsion, or encapsulated form rather than neat crystals. During scale-up, calculate the addition from the actual lot assay, minimize unnecessary heat and open-air holding, and compare pilot and commercial batches for color, potency, physical behavior, and finished-product uniformity. Projects requiring dosage-form selection, supporting ingredients, or process development can be reviewed through custom supplement formulation.

Formulation Guidance

  1. Low inclusion range: At approximately 10–50 mg per unit, use geometric dilution or a standardized premix to reduce hotspots and sampling variation.
  2. Medium inclusion range: At approximately 50–150 mg per unit, compare direct powder filling, oil suspension, granulated material, and carrier-adsorbed approaches.
  3. Higher inclusion range: At approximately 150–300 mg per unit, confirm capsule size, tablet weight, softgel fill volume, serving configuration, and manufacturing feasibility. These are formulation ranges, not intake recommendations.
  4. Assay correction: Calculate the required addition from the actual lot-specific COA rather than assuming exactly 100% potency.
  5. Water-solubility risk: Crystalline ubiquinone is practically insoluble in water. Use an oil phase, suspension, emulsion, suitable carrier, or separately qualified dispersible form.
  6. Segregation risk: Differences in particle size and density may create non-uniform blends. Match the excipient profile and prepare a concentrated premix before final dilution.
  7. Stability risk: Minimize strong light, excessive headspace, high temperature, prolonged open-air holding, and repeated container opening.
  8. Carrier and antioxidant synergy: Screen lipid carriers for viscosity, suspension behavior, filling consistency, and storage stability. Mixed tocopherols or another compatible antioxidant system may also be evaluated.
  9. Formula synergy: CoQ10 may be evaluated with selected vitamins, minerals, lipids, or antioxidant ingredients, subject to regional regulations and finished-product claim review.
  10. Process and QA tip: Use granulation, carrier adsorption, or late-stage addition where appropriate. Finished-product testing should verify active content, uniformity, appearance, packaging compatibility, and stability.

Packaging, Storage & Logistics

ItemB2B Supply Details
Sample PackingSealed light-protective bag or bottle for laboratory and formulation evaluation
Small Bulk PackingMoisture- and light-protective foil or multilayer bag
Bulk PackingProtective inner liner in a labeled fiber drum or carton
Pack SizeConfirmed according to order quantity, production use, and shipment requirements
Pack DivisionSmaller divided packs may be requested to reduce repeated opening
Optional ProtectionNitrogen flushing or reduced headspace for stability-sensitive projects
Label InformationProduct name, lot number, net weight, manufacturing or retest information, and storage conditions
PalletizationExport pallet configuration available according to shipment size and destination
Shelf LifeTypically 24 months unopened under recommended storage conditions
Storage ConditionsKeep sealed in a cool, dry, and light-protected area
After OpeningReseal promptly and minimize repeated exposure to air, light, heat, and humidity

Packaging should be approved with the product specification. Packaging integrity, headspace, repeated opening, light exposure, and transit temperature can affect material after lot release. Buyers using one shipment across several production runs should select pack divisions that minimize partially filled containers and repeated exposure. Keep the approved packaging configuration consistent across repeat orders. Receiving teams should inspect seals, container condition, lot identification, labels, packing quantities, and accompanying documents before releasing the material into quarantine or production storage.

MOQ, Lead Time, Documents & Inquiry

Commercial Supply Information

ItemSupply Information
Standard MOQConfirmed according to specification, pack size, stock status, testing scope, shipment plan, and destination
Sample PolicySamples are available for supplier qualification, formulation trials, document review, and pilot evaluation
Lead TimeEstimated after stock, specification, packaging, testing, quantity, and document requirements are reviewed
Testing SupportRoutine or third-party testing is confirmed by agreed method and scope
Certification ReviewCertificates are confirmed by source, facility, product scope, and market
Shipping SupportCourier, air freight, sea freight, export packing, and freight handover are coordinated according to the order
Inquiry RequirementsRequired assay, physical form, application, quantity, destination, packaging, testing, documents, and preferred schedule

Document Availability

Document GroupTypical Available Documents
Quality and TechnicalSample COA, lot-specific COA, TDS, and approved product specification
SafetySDS
Product StatusAvailable allergen, GMO, gluten, vegan, and irradiation statements
Origin and ComplianceCountry-of-origin information, available process declarations, and facility- or product-specific certificates
TestingAgreed internal or third-party laboratory report
ExportCommercial invoice, packing list, and agreed shipment documents

Certificates are confirmed against the actual facility, product scope, issuing organization, and validity period. Facility registrations or quality-system certificates must not be presented as product approval.

Essencefield’s global supplement supply support coordinates packing, shipment documents, freight handover, and repeat-order planning. Submit the required assay, dosage format, quantity, destination, packaging, testing, and document needs to request a Coenzyme Q10 Powder sample or commercial quotation.

Request Ingredient Specs & Quote

Share your target specification, application, quantity and document needs. We will help confirm suitable options, COA/TDS/SDS support and bulk supply details.

Related Ingredients for Formulation

Explore related ingredients for formula comparison, complementary applications and alternative sourcing options across food, beverage, supplement and wellness projects.