Disodium EDTA Powder

Disodium EDTA Powder is a chelating agent used to bind trace metal ions that can influence color, flavor and formulation stability. This white crystalline powder is suitable for beverages, sauces, dressings and cosmetic water phases where metal-ion control, preservative system support and consistent aqueous processing performance are important in beverage, sauce and cosmetic formulation trials at scale and routine production.

Top Key Specs

ItemB2B Specification
Product nameDisodium EDTA Powder
Chemical nameDisodium ethylenediaminetetraacetate
Common reference namesEDTA disodium salt powder, disodium edetate powder, EDTA-Na₂ powder, disodium EDTA
Ingredient categorySynthetic chelating agent powder / formulation stabilizer
Source or raw material originChemically synthesized ingredient; raw material source and manufacturing route confirmed by project
CAS referenceCommonly referenced as CAS 139-33-3 for disodium salt and CAS 6381-92-6 for disodium salt dihydrate; final CAS confirmed by agreed specification
Grade optionsFood, cosmetic, industrial, or project-specific grade according to application and destination market requirements
Standard specificationAssay-controlled material with identity, assay, loss on drying, pH, particle size, insolubles, heavy metals, and microbiology reviewed by agreed specification
Assay / purityTypically 99.0–101.0% by complexometric titration or according to agreed specification
Active standardization basisStandardized by assay and, when required, supported by chelation value or solution clarity testing
Processing methodSynthesis, crystallization, drying, milling, sieving, metal detection, sampling, and batch release inspection
AppearanceWhite to off-white crystalline powder
Odor and tasteLow odor; sensory impact should be checked in beverages, gummies, and low-flavor powder systems
CarrierNormally supplied without carrier; carrier-based premix support available by project
Solubility / dispersibilityFreely soluble in water; not oil-soluble; pre-dissolution is recommended for liquid systems and high-solids formulas
pH behaviorTypically tested in aqueous solution at an agreed concentration; final range depends on grade and salt form
Mesh size / particle sizeCommonly supplied around 60–100 mesh; custom particle size available for dissolution speed, dust control, or blend uniformity
Loss on dryingControlled according to hydration form and agreed specification
Insoluble matterLow-insoluble control available for clear beverages, gels, emulsions, and appearance-sensitive applications
Residue on ignitionTested according to agreed specification and release method
Bulk density / flowabilityReported when required for automated dosing, capsule filling, tableting, or premix projects
StabilityStable under dry, sealed storage; protect from humidity, condensation, and incompatible storage conditions
Application compatibilitySuitable for capsules, tablets, powder blends, stick packs, beverages, gummies, emulsions, and selected personal care systems after compatibility testing
Shelf lifeTypically 24 months in unopened original packaging when stored dry and sealed
OriginChina or project-confirmed manufacturing origin
Available documentsCOA, TDS, SDS, specification sheet, allergen statement, GMO statement, gluten statement, vegan statement, irradiation statement, country of origin statement, and project-related documents

Typical COA Limits

Physical & Chemical ParameterTypical Limit or Review Basis
AppearanceWhite to off-white crystalline powder
IdentificationFTIR, sodium confirmation, complexometric reaction, or agreed identity method
AssayTypically 99.0–101.0%, as supplied basis
Chelation valueAvailable when functional metal-binding capacity is required
Loss on dryingControlled according to hydration form and agreed specification
pHTested in aqueous solution at agreed concentration
Insoluble matterControlled for clear-liquid, beverage, gel, or emulsion applications
Particle size60–100 mesh typical, or customized by project
Bulk densityReported when required for filling, dosing, or blending validation
ChlorideAvailable when ionic carryover may affect formula stability
SulfateAvailable when required by customer specification
Iron / copperReported or controlled for oxidation-sensitive formulas when required
NTA or related impurity screenAvailable according to customer quality policy or destination market requirements
Residual solventsTested when relevant to process or agreed specification
Residue on ignitionControlled according to agreed specification
Clarity of solutionAvailable for beverage, surfactant, gel, or transparent-liquid systems
Odor / colorConfirmed by sensory and visual inspection
Heavy MetalsTypical Limit
Lead≤1.0 mg/kg or customer-specific limit
Arsenic≤1.0 mg/kg or customer-specific limit
Cadmium≤1.0 mg/kg or customer-specific limit
Mercury≤0.1 mg/kg or customer-specific limit
Total heavy metalsControlled according to agreed specification when required
MicrobiologyTypical Limit
Total plate count≤1,000 CFU/g or agreed specification
Yeast and mold≤100 CFU/g or agreed specification
E. coliNegative according to agreed test size
SalmonellaNegative according to agreed test size
Other pathogensAvailable according to destination market or customer specification

Batch Release & Quality Review

Each batch of Disodium EDTA Powder may be reviewed through identity confirmation, raw material source records, production batch records, assay result, loss on drying, pH, particle size, insoluble matter, residue profile, microbiology, heavy metals, odor, color, retained samples, and COA consistency. For performance-sensitive applications, additional review may include chelation value, clarity at use concentration, chloride, sulfate, iron, copper, or related impurity screening. Batch release should not rely on assay alone because EDTA performance depends on active chelant content, hydration form, dissolution behavior, particle size, and compatibility with the finished matrix. Batch-to-batch comparison can support supplier approval, formula validation, distributor qualification, and contract manufacturing continuity.

Features & Benefits

Disodium EDTA Powder is used in B2B formulation when trace metal control, solution stability, and specification consistency are part of the product design. It is commonly evaluated in aqueous systems, premixes, tablets, capsules, emulsions, beverages, gummies, and personal care formulas where metal ions may influence color, odor, clarity, preservative behavior, or ingredient interaction. Application-specific testing is recommended because performance depends on pH, water hardness, metal load, ionic strength, processing sequence, and destination market requirements.

  • Assay-controlled EDTA disodium salt powder supports accurate formulation at low inclusion levels.
  • Synthetic source and controlled manufacturing records support ingredient traceability and supplier approval.
  • FTIR identity, complexometric assay, sodium confirmation, and optional chelation value testing can support QA review.
  • Custom particle size options help balance dissolution rate, dust control, flowability, and blend uniformity.
  • Low-insoluble specification options help reduce haze, specking, and visible residue in clear or light-colored systems.
  • Moisture-controlled packing reduces caking risk during storage, transport, and partial-bag handling.
  • Water solubility supports pre-dissolution before acids, minerals, thickeners, flavors, colors, or high-solids components are added.
  • Optional chloride, sulfate, iron, copper, and related impurity testing helps align the material with customer-specific quality agreements.
  • COA, TDS, SDS, and compliance documents support importers, distributors, private label companies, and contract manufacturers.
  • Bulk supply and custom specification support are available for assay range, particle size, insoluble matter, chelation value, testing package, and packaging format.

Applications & Formulation Ideas

Primary Application Formats

FormatPractical Formulation Notes
CapsulesSuitable for dry blends when particle size, assay, and content uniformity are controlled. Geometric dilution is recommended for low-level addition.
TabletsCan be used after checking flowability, compression behavior, lubricant compatibility, segregation risk, and uniformity in the final blend.
Powder blendsBest handled as a pre-sieved micro-ingredient. Confirm blend uniformity when used with high-density minerals, proteins, flavors, or sweeteners.
Stick packs and sachetsSuitable when moisture exposure, flowability, caking risk, and pouch compatibility are validated under intended storage conditions.
Beverage powdersPre-dissolution or rapid dispersion testing is recommended. Evaluate clarity, sedimentation, pH behavior, and sensory neutrality.
RTD drinksUsually added to the water phase before acids, colors, flavors, thickeners, high-Brix syrups, or electrolyte systems.
GummiesRequires testing through water-phase addition, heating, pH adjustment, gelation, final moisture, and texture review.
EmulsionsCommonly evaluated in oil-in-water systems where trace metal control may support color, odor, and preservative consistency.
Personal care systemsSuitable for selected creams, lotions, gels, cleansers, and surfactant systems after formula compatibility and regulatory review.
Private label projectsSupports custom specification, supplier approval documents, formulation review, and contract manufacturing documentation needs.

Application Formats Requiring Extra Testing

FormatExtra Testing Recommended
Clear beveragesTest clarity, haze, sediment, color shift, pH drift, metal burden, and sensory impact under real-time and accelerated conditions.
High-mineral formulasEvaluate interaction with calcium, magnesium, zinc, iron, copper, and electrolyte systems because mineral load may influence chelation capacity.
Cationic systemsScreen for precipitation, viscosity drift, or performance change when cationic surfactants, polymers, or actives are present.
High-electrolyte powdersCheck dissolution order, ionic strength, caking risk, and uniformity in hydration, effervescent, or mineral drink systems.
Gummies and heated systemsConfirm heat exposure, pH adjustment, holding time, gelation, final texture, and finished moisture before scale-up.
Transparent gels and white emulsionsRequest low-insoluble control and test visible particles, specks, clarity, and color consistency at use concentration.

Formulation Notes

  • Typical prototype inclusion in beverages may start at low ppm levels, but the final level should be based on water hardness, ingredient metal burden, pH, process, and destination market requirements.
  • In personal care emulsions, low percentage-level prototypes are commonly evaluated, but compatibility should be confirmed with the preservative system and stability plan.
  • In capsules and tablets, pre-blending is recommended because Disodium EDTA Powder may be used at a much lower level than major excipients.
  • For powder blends, verify assay uniformity after mixing and after transport simulation when formula density differences are significant.
  • For RTD systems, dissolve EDTA-Na₂ in the water phase before adding acids, minerals, colors, flavors, thickeners, or syrups.
  • For clear liquids, test clarity at actual use concentration rather than relying only on general water-solubility data.
  • For high-mineral products, evaluate whether added minerals consume chelation capacity or affect finished product positioning.
  • For gummies, check whether the ingredient remains dissolved after heating, pH adjustment, and gel formation.
  • For humid manufacturing rooms, keep liners sealed during staging and avoid long exposure before weighing.
  • For QA release, align incoming inspection with identity, assay, LOD, particle size, insolubles, heavy metals, microbiology, and any customer-specific impurity requirements.

Packaging, Storage & Logistics

ItemB2B Supply Details
Sample packingSmall sample packs available for R&D testing, supplier approval, and formulation screening
Bulk inner packingSealed food-grade polyethylene liner or moisture-barrier inner bag
Bulk outer packing25 kg carton, kraft bag, fiber drum, or project-confirmed export packing
Label informationProduct name, batch number, net weight, manufacture date, expiry or retest date, storage condition, and country of origin as required
PalletizationExport pallet options available with stretch wrap, carton protection, pallet labels, and shipping marks
Shelf lifeTypically 24 months unopened under recommended storage conditions
Storage conditionsStore in a cool, dry, sealed area away from humidity, condensation, strong odors, and incompatible materials
Humidity controlKeep liners tightly closed after opening; avoid repeated humidity cycling that may cause caking or handling variation
Temperature controlNormal dry warehouse storage is usually suitable; avoid high heat, direct sunlight, and container condensation
Shipping optionsCourier sample shipment, air freight, sea freight, and consolidated export shipment available by order size
Export documentsCommercial invoice, packing list, COA, SDS, certificate of origin, and other project-related documents when required
Long-distance shippingMoisture-barrier packing, pallet protection, container loading review, and route-specific humidity control are recommended for humid destinations
Handling after openingReseal immediately, use clean dry tools, prevent cross-contamination, and record partial-bag use for traceability

MOQ, Lead Time, Documents & Inquiry

ItemSupply Information
Standard MOQTypically 25 kg for commercial supply; smaller sample quantities can be discussed for qualification
Sample policySamples available for R&D evaluation, supplier approval, formulation screening, and document review
Standard lead timeUsually 7–15 business days for standard specification, subject to stock, testing, and packing schedule
Custom specification lead timeConfirmed by project when extra testing, particle size adjustment, low-insoluble control, impurity limits, or special packaging is required
Bulk supply supportPallet supply, recurring shipment planning, distributor support, and contract manufacturing supply coordination available
Custom manufacturing supportAssay control, particle size adjustment, low-insoluble specification, chelation value testing, impurity screening, and project-specific COA setup
OEM / private label supportIngredient supply, documentation, formulation support, and specification alignment for private label supplement and personal care projects
Available documentsCOA, TDS, SDS, specification sheet, allergen statement, GMO statement, gluten statement, vegan statement, irradiation statement, country of origin statement, and project-related documents
Testing supportIdentity, assay, loss on drying, pH, particle size, insolubles, heavy metals, microbiology, chloride, sulfate, chelation value, and impurity screening when required
Buyer information neededTarget specification, grade, application format, order quantity, destination market, document checklist, packaging needs, testing requirements, and expected timeline

For quotation and technical review, please provide the target specification, grade, application format, order quantity, destination market, document checklist, testing requirements, packaging needs, and expected timeline. Essencefield can help confirm suitable Disodium EDTA Powder options for bulk supply, custom specification projects, private label programs, distributor sourcing, and contract manufacturing use.

Request Ingredient Specs & Quote

Share your target specification, application, quantity and document needs. We will help confirm suitable options, COA/TDS/SDS support and bulk supply details.

Related Ingredients for Formulation

Explore related ingredients for formula comparison, complementary applications and alternative sourcing options across food, beverage, supplement and wellness projects.