Natamycin Powder

Natamycin Powder is a fermentation-derived preservative ingredient also known as pimaricin, E235, or INS 235. It is most suitable for permitted surface applications such as coatings, dips, sprays, and selected dairy or bakery systems. Because dispersion and coverage affect performance, formulators should review particle behavior, application method, residue expectations, labeling needs, and trial conditions before commercial use in target matrices.

Top Key Specs

ItemTypical B2B Specification
Product nameNatamycin Powder
Common reference namesNatamycin, Pimaricin, E235, INS 235
Ingredient categoryFermentation-derived food additive preservative
Source or raw material originProduced through controlled microbial fermentation, followed by purification, drying, milling, sieving, and packing
Standard specificationCarrier-free Natamycin Powder or carrier-based preparation according to agreed specification
Assay / purityAssay-controlled grade; exact natamycin content confirmed by project specification and batch COA
Active standardizationStandardized by natamycin assay, typically tested by HPLC or another agreed validated method
Identifier supportCAS number, E number, INS number, and product identification details available on specification documents when required
GradeFood additive grade; destination-market suitability should be confirmed by buyer QA and regulatory teams
AppearanceWhite to off-white fine powder
Odor and tasteMild, characteristic odor; sensory profile confirmed by batch inspection
Carrier optionsCarrier-free, lactose-based, dextrose-based, or other agreed carrier systems depending on formulation and labeling needs
Particle sizeFine powder; mesh or particle size distribution can be customized for spray, dip, coating, or dry blending projects
Solubility / dispersibilityPractically insoluble in water; generally used as a suspension or dispersion rather than a fully dissolved solution
pH behaviorApplication-dependent; compatibility should be tested in the target coating, dip, film, or food matrix
Moisture / loss on dryingControlled according to agreed specification to support flowability, caking resistance, and storage stability
Residue on ignition / ashTested when required by customer specification or destination-market documentation
Bulk densityAvailable upon request for dosing, filling, premix, and process evaluation
FlowabilityInfluenced by assay grade, carrier system, moisture, particle size, and packing density
Stability focusSensitive to strong light, high humidity, oxidizing conditions, and unsuitable line-side exposure
Application compatibilitySurface coatings, dips, sprays, edible films, cheese surface systems, casing systems, powder premixes, and approved food additive applications
Main QA focusIdentity, assay, related substances, particle size, moisture, microbiology, heavy metals, carrier declaration, and suspension behavior
Shelf lifeTypically 24 months unopened under recommended storage; final shelf life confirmed by batch and packaging format
OriginChina; country of origin statement available
Available documentsCOA, TDS, SDS, specification sheet, allergen statement, GMO statement, gluten statement, vegan statement, irradiation statement, origin statement, and project-specific declarations

Typical COA Limits

The following COA categories are commonly reviewed for Natamycin Powder in B2B purchasing, supplier approval, and formulation projects. Final limits should be confirmed by agreed specification, assay grade, carrier system, application format, and destination market requirements.

Physical & Chemical ItemTypical Control Approach
AppearanceWhite to off-white powder
IdentificationConforms by HPLC, UV profile, or agreed validated method
AssayReported as natamycin content according to purchased grade and contract specification
Related substancesControlled when required to evaluate degradation, storage impact, or processing exposure
Moisture / loss on dryingControlled to reduce caking risk and protect dispersion performance
Residue on ignition / ashTested according to agreed specification
Particle size / meshSieve or laser diffraction data available when required
Bulk densityReported upon request for dosing, filling, and premix design
Carrier declarationConfirmed when lactose, dextrose, or other carrier systems are used
Dispersibility / re-suspendabilityAvailable as project-specific testing for sprays, dips, coatings, and recirculating systems
Residual solventsTested when relevant to production route or customer specification
Light and storage sensitivityReviewed through handling instructions and packaging selection
Microbiological ItemTypical Limit
Total plate countTested according to agreed specification
Yeast and moldTested according to agreed specification
ColiformsTested according to agreed specification
E. coliNegative according to agreed method and sample size
SalmonellaNegative according to agreed method and sample size
Staphylococcus aureusAvailable when required by customer specification
Heavy MetalsTypical Control Approach
LeadTested according to agreed specification
ArsenicTested according to agreed specification
CadmiumTested according to agreed specification
MercuryTested according to agreed specification
Total heavy metalsAvailable when required by buyer documentation checklist
Product-Specific Quality IndicatorWhy It Matters
Natamycin assaySupports dosing calculation, formulation adjustment, and batch release
Chromatographic identityConfirms authenticity and supports supplier approval
Related substancesHelps evaluate degradation risk from light, heat, oxidants, or unsuitable storage
Particle size distributionAffects spray uniformity, settling rate, coating coverage, and dry blend uniformity
Suspension behaviorCritical for dips, sprays, coating tanks, and recirculating systems
Carrier contentSupports label review, allergen review, dosing math, and formulation compatibility
Water activityHelps evaluate caking risk and storage stability when required
Sensory inspectionConfirms powder color, odor, and physical condition before release

Batch Release & Quality Review

Each batch of Natamycin Powder may be reviewed through identity confirmation, source traceability, production record verification, assay testing, moisture control, particle size review, microbiological testing, heavy metal screening, and visual-sensory inspection. For carrier-containing grades, carrier type and declared concentration should be checked against the purchasing specification, COA, and label review requirements. Because natamycin is typically used as a suspension in surface-treatment systems, QA review should not rely only on assay; particle size, wet-out behavior, re-suspendability, caking condition, odor, color, and batch-to-batch comparison are also important. Retained samples can support supplier qualification, complaint investigation, and future comparison testing. For projects with strict line performance requirements, buyers may request PSD data, related-substance testing, water activity, carrier verification, and application-specific dispersion testing before bulk release.

Features & Benefits

    • Fermentation-derived Natamycin Powder suitable for B2B food additive projects where the ingredient is permitted by the destination market.
    • Supplied by Essencefield as a bulk ingredient manufacturer and supplier for food additive, coating, dip, spray, and premix projects.
    • Available as carrier-free material or carrier-based preparation to support different dosing, dispersion, handling, and label review requirements.
    • Assay-controlled specification helps purchasing and QA teams align raw material release with formulation calculations.
    • Particle size customization supports spray, dip, coating, and dry blend projects where sedimentation, dusting, or nozzle performance must be managed.
    • Practically insoluble behavior supports surface-retention strategies but requires correct suspension design, agitation, and application validation.
    • Moisture-controlled and light-protective packaging options help reduce caking, flowability change, and active degradation risk.
    • Batch traceability supports supplier approval, import review, distributor documentation, and customer complaint investigation.
    • COA-to-specification review helps confirm that identity, assay, microbiology, heavy metals, particle size, and sensory condition match the agreed purchase standard.
    • Documentation support includes COA, TDS, SDS, specification sheet, origin statement, allergen statement, GMO statement, gluten statement, vegan statement, and irradiation statement when required.
    • Custom specification support is available for assay level, carrier type, particle size, microbiology, heavy metals, packing size, and project-specific testing.

Applications & Formulation Ideas

Primary Application Formats

FormatPractical Formulation Notes
Cheese coatingsCommonly evaluated in surface coating systems where permitted. Formulators should validate coating viscosity, pickup rate, surface coverage, drying behavior, and compatibility with emulsifiers or film-forming systems.
Dip systemsRequires continuous or periodic agitation because Natamycin Powder behaves as a suspension. Settling risk, bath concentration drift, contact time, drainage, and surface deposition should be measured during pilot runs.
Spray applicationsParticle size distribution should be matched with nozzle type, spray pressure, filtration strategy, and tank agitation. Coarse particles may settle faster, while overly fine powders may increase dusting during handling.
Edible film systemsSuitable for evaluation in film-forming matrices where surface retention is required. Compatibility with polymer, plasticizer, pH, drying temperature, and final film clarity should be tested.
Casing surface systemsMay be evaluated for casing surface applications where permitted. Uniform wetting, casing material compatibility, application temperature, and post-application drying conditions should be validated.
Powder premixesCan be pre-blended with suitable carriers or processing aids to improve dosing accuracy. Blend uniformity, particle segregation, and carrier declaration should be reviewed.
Private label food additive projectsSuitable for contract manufacturing programs requiring specification alignment, COA consistency, documentation support, and batch traceability.

Application Formats Requiring Extra Testing

FormatExtra Testing Recommended
Beverage powdersNatamycin Powder is not designed as a fully soluble beverage ingredient. Dispersibility, visible sediment, label suitability, application purpose, and destination-market allowance must be confirmed before development.
RTD drinksRequires careful review because low solubility may create sediment, ring formation, or visible particles. Heat exposure, pH, light, and permitted use should be evaluated.
GummiesApplication is project-dependent. Heat process, water activity, dispersion uniformity, taste impact, and permitted use must be reviewed before pilot production.
TabletsDirect compression requires evaluation of flowability, carrier system, dose uniformity, compression behavior, and friability. Custom granulation or premix support may be needed.
CapsulesCapsule filling can be evaluated when the ingredient is used in a permitted B2B formulation. Bulk density, flowability, carrier choice, and blend uniformity should be checked.
Functional barsProcessing temperature, fat phase interaction, water activity, particle visibility, and regulatory suitability require project-specific confirmation.
High-shear systemsStrong mixing can improve wetting but may introduce foaming, heat, or matrix changes. Pilot testing should define mixing speed, time, and hold conditions.

Formulation Notes

Natamycin Powder should be engineered as a suspension-delivered ingredient rather than treated as a soluble powder. For coating and dip projects, prototype concentration should be calculated from the permitted use model, target surface deposition, pickup rate, and active assay of the purchased grade. Carrier-free grades may support higher active content per kilogram, while carrier-based preparations may improve wet-out, dosing convenience, and process handling. Pre-wetting into a small side stream before addition to the main tank can reduce floating clumps and shorten make-down time. Agitation should be strong enough to maintain suspension uniformity but not so aggressive that it destabilizes the coating matrix. Light exposure should be minimized during storage and line-side handling. Oxidizing sanitation residues should be separated from working solutions. Fine filtration should be avoided unless validated, because it may remove suspended active. QA release should include application-relevant checks such as particle size, dispersibility, moisture, assay, and retained sample comparison.

Packaging, Storage & Logistics

ItemB2B Supply Details
Sample packingSmall foil bags or sealed sample packs for laboratory evaluation and supplier approval
Bulk inner packingFood-grade PE bag, foil bag, or light-protective liner according to product sensitivity and customer requirement
Bulk outer packingFiber drum, carton, or agreed export packing suitable for long-distance transport
Common bulk sizeOften supplied in 1 kg, 5 kg, 10 kg, or 25 kg formats depending on grade and order volume
Label informationProduct name, batch number, net weight, production date, retest or expiry date, storage condition, and origin information
PalletizationExport palletization available upon request with carton or drum protection and shipping marks
Shelf lifeTypically 24 months unopened under recommended storage; confirmed by batch specification
Storage conditionsStore sealed in a cool, dry, light-protected area away from heat, humidity, direct sunlight, and oxidizing materials
Humidity controlKeep tightly closed after opening; use desiccant or controlled storage where humidity risk is high
Temperature controlAvoid hot warehouse zones, direct sun exposure, and prolonged high-temperature transit where possible
Shipping optionsAir, sea, courier sample shipment, or forwarder-based export shipment according to order size and destination
Export documentsCommercial invoice, packing list, COA, SDS, TDS, origin statement, and project-specific documents when required
Long-distance shipping considerationsUse moisture-resistant and light-protective packing; confirm destination documentation before dispatch
Handling after openingReseal immediately, minimize light exposure, avoid contamination, and use opened material according to site QA procedures

MOQ, Lead Time, Documents & Inquiry

Standard MOQ is typically confirmed by grade, assay level, carrier system, packing format, and current production schedule. Trial samples may be available for laboratory evaluation, supplier approval, dispersion testing, or pilot production. Standard lead time is usually confirmed after specification review, while custom assay, carrier, particle size, microbiology, heavy metal, or additional documentation requirements may require extra testing time before shipment.

Essencefield supports bulk supply, custom manufacturing, OEM projects, private label food additive programs, contract manufacturing support, formulation review, particle size customization, carrier adjustment, blend development, and project-specific documentation support. Available documents may include COA, TDS, SDS, specification sheet, allergen statement, GMO statement, gluten statement, vegan statement, irradiation statement, country of origin statement, and other documents required for supplier qualification or import review. Testing support can be arranged for assay, identity, particle size, moisture, microbiology, heavy metals, related substances, carrier declaration, and application-specific suspension behavior.

For a Natamycin Powder quotation, please provide the target specification, application format, required assay or preparation type, order quantity, destination market, document checklist, testing requirements, packaging needs, carrier preference, particle size target, and expected timeline. Our team will review the project details and recommend a suitable grade, COA scope, packing format, and supply plan for your purchasing, formulation, and QA approval process.

Request Ingredient Specs & Quote

Share your target specification, application, quantity and document needs. We will help confirm suitable options, COA/TDS/SDS support and bulk supply details.

Related Ingredients for Formulation