

Propylparaben Powder, also called propyl 4-hydroxybenzoate or CAS 94-13-3, is a carrier-free crystalline preservative active supplied for B2B preservative-system development. Available in standard or customized assay, impurity, and particle-size specifications, it is evaluated for permitted personal care, liquid, gummy, powder, tablet, and capsule projects by contract manufacturers, private label companies, distributors, formulators, and QA teams.
| Item | Typical B2B Specification |
|---|---|
| Product name | Propylparaben Powder |
| Chemical name | Propyl 4-hydroxybenzoate |
| Common reference names | Propylparaben, propyl p-hydroxybenzoate, propyl 4-hydroxybenzoate powder, propyl 4-HB |
| CAS number | 94-13-3 |
| Ingredient category | Preservative active / functional compound |
| Source or raw material origin | Synthetic esterification route; raw material and batch source confirmation available upon request |
| Standard specification | Typically ≥99.0% assay by HPLC, confirmed according to the agreed specification |
| Custom specification options | Assay range, related substances, particle size, PSD D10/D50/D90, residual solvent panel, microbiology limits, heavy metal limits, and documentation package |
| Grade | Cosmetic, food, or pharma-related grade options may be discussed according to destination market and application requirements |
| Processing method | Esterification, purification, crystallization, drying, milling, sieving, packing, and final QC release |
| Appearance | White to off-white crystalline powder |
| Odor and taste | Neutral to faint characteristic odor; sensory impact should be evaluated for permitted oral or fragrance-sensitive formats |
| Carrier | No carrier; supplied as a 100% active powder unless a custom blend is agreed |
| Assay / purity | Typically ≥99.0%; exact limit confirmed by project |
| Particle size | Commonly 80 mesh; finer milling or PSD-controlled grades available for clarity-sensitive or low-dose systems |
| Solubility / dispersibility | Slightly soluble in water; generally evaluated through alcohol, glycol, or approved mixed-solvent premix systems |
| pH behavior | Finished-formula pH compatibility should be confirmed by application testing, especially under alkaline or high-temperature processing |
| Loss on drying | Commonly controlled at low moisture levels; limit confirmed on specification |
| Residue on ignition | Tested according to agreed specification when required |
| Bulk density | Varies by milling cut and packing condition; typical values can be provided for filling and blending evaluation |
| Flowability | Free-flowing crystalline powder under dry handling; humidity control is recommended |
| Color impact | Minimal in most systems when properly dissolved or dispersed |
| Flavor impact | Low odor profile, but application-specific sensory testing is recommended for permitted oral formats |
| Stability | Stable when sealed, dry, and protected from strong bases, oxidizers, heat abuse, and odor cross-contact |
| Application compatibility | Evaluated for preservative systems, solvent premixes, creams, lotions, washes, gels, and permitted oral-format projects after validation |
| Shelf life | Typically 24 months unopened when stored under recommended conditions |
| Origin | China, unless otherwise confirmed by lot |
| Main applications | Preservative-system development, distributor bulk supply, contract manufacturing, private label formulation support, and QA-controlled ingredient sourcing |
| Available documents | COA, TDS, SDS, specification sheet, allergen statement, GMO statement, gluten statement, vegan statement, irradiation statement, origin statement, and project-related documents |
Propylparaben Powder is not a botanical extract and should be evaluated as a chemical preservative active. Buyer approval should focus on identity, HPLC assay, related substances, particle-size behavior, residual solvent risk, moisture control, microbiology, heavy metals, and destination-market suitability. Because the ingredient has limited water solubility, a passing assay does not automatically confirm finished-formula performance. For scale-up, the most useful specification package usually combines assay, impurity profile, loss on drying, melting range, particle size distribution, and a practical solvent-phase clarity check in the customer’s selected processing system.
| Physical / Chemical Parameter | Typical Limit or Control Method |
|---|---|
| Appearance | White to off-white crystalline powder |
| Identification | FTIR and/or HPLC retention time compared with reference standard |
| Assay | Typically ≥99.0% by HPLC, or according to agreed specification |
| Related substances | Individual and total impurities controlled according to customer specification |
| Melting range | Tested as an identity and crystallization consistency indicator |
| Loss on drying | Typically ≤0.5%, or according to agreed specification |
| Residue on ignition | Controlled when required by customer or destination market |
| Particle size / mesh | 80 mesh typical; D10/D50/D90 reporting available for PSD-controlled projects |
| Bulk density | Reported when required for filling, blending, or automated dosing evaluation |
| Solubility check | Solvent-phase clarity or time-to-clear testing available when required |
| Odor | Neutral to faint characteristic odor; abnormal odor reviewed before release |
| Color consistency | Compared with approved reference sample or retained lot standard |
| Residual solvents | GC panel available when purification route or market requirement calls for it |
| Homolog profile | Optional review for other paraben carryover or related ester peaks |
| Hydrolysis-related marker | Available for high-pH or alkaline-process risk evaluation |
| Heavy Metals | Typical Limit |
|---|---|
| Lead | ≤1.0 ppm, or customer-specific limit |
| Arsenic | ≤1.0 ppm, or customer-specific limit |
| Cadmium | ≤1.0 ppm, or customer-specific limit |
| Mercury | ≤0.5 ppm, or customer-specific limit |
| Total heavy metals | ≤10 ppm, or according to agreed specification |
| Microbiological Parameter | Typical Limit |
|---|---|
| Total aerobic microbial count | ≤1,000 cfu/g |
| Total yeast and mold count | ≤100 cfu/g |
| Escherichia coli | Absent in 1 g |
| Salmonella | Absent in 25 g |
| Staphylococcus aureus | Absent in 1 g |
| Pseudomonas aeruginosa | Tested when required for personal care or liquid-system projects |
| Product-Specific Quality Indicator | Why It Matters |
|---|---|
| HPLC assay | Confirms active content for formulation calculation and receiving release |
| Related substances | Helps control odor, appearance, stability, and batch-to-batch consistency |
| Particle size distribution | Influences dissolution speed, visible particulates, and clarity risk |
| Solvent-phase time-to-clear | Connects incoming QC with actual manufacturing behavior |
| Moisture control | Reduces caking, flow issues, and long-distance shipping complaints |
| Melting range | Supports quick identity and crystallization consistency screening |
| Residual solvent panel | Supports QA approval for market-sensitive or tightly controlled projects |
| Retained sample comparison | Helps evaluate color, odor, particle feel, and lot continuity |
Before release, each batch of Propylparaben Powder may be reviewed against the agreed specification, purchase order, and retained reference sample. The review normally includes identity confirmation, raw material source record, production batch record, HPLC assay result, related-substance profile, moisture or loss on drying, residue on ignition when required, particle size or mesh, bulk density when specified, microbiology, heavy metals, appearance, odor, and COA consistency. For clarity-sensitive or solvent-premix applications, the batch can also be evaluated through PSD reporting and a solvent-phase dissolution check using a customer-defined alcohol, glycol, or mixed-solvent system. Retained samples support traceability, complaint investigation, deviation review, and batch-to-batch comparison. Optional testing, including residual solvents, homolog carryover, heavy-metal tightening, extended impurity mapping, and market-specific microbiology, should be confirmed before order placement.
Propylparaben Powder performs best when procurement, QA, and formulation teams treat it as a solvent-delivered preservative active rather than a simple water-soluble powder. Clarity defects or uneven distribution often result from incomplete dissolution, coarse PSD, or dilution below the solubility threshold. For this reason, specifications should not stop at assay alone. A stronger approval package defines HPLC assay, related substances, loss on drying, particle size, solvent-phase clarity, and finished-formula preservative validation. This approach helps buyers reduce supplier-change risk while giving QA and R&D teams measurable acceptance criteria for scale-up and repeat orders.
| Format | Practical Formulation Notes |
|---|---|
| Creams and lotions | Commonly evaluated in solvent-phase premixes before cool-down addition. Check emulsion stability, odor, viscosity, pH, and finished-product preservation validation. |
| Shampoos and body washes | Premix dosing helps reduce undissolved particles. Evaluate surfactant compatibility, clarity, viscosity change, fragrance interaction, and storage stability. |
| Clear gels and toners | Require finer PSD, full premix clarity, and a short clarity hold to detect delayed crystallization or haze before commercial approval. |
| Wet wipe solutions | Should be used only as part of a complete preservation system. Test compatibility with nonwoven substrate, fragrance, chelator, and booster system. |
| Hydroalcoholic products | Alcohol or mixed-solvent systems may improve dissolution. Confirm evaporation loss, odor impact, active retention, and packaging compatibility. |
| OEM preservative concentrates | Suitable for standardized premix workflows where contract manufacturers need repeatable dosing across multiple production sites. |
| Personal care gels and washes | Evaluate solubilizer level, viscosity system, fragrance load, final pH, and low-temperature storage before commercial approval. |
| Distributor repacking projects | Require moisture-controlled handling, clean repacking procedures, retained sample management, and original batch traceability. |
| Format | Why Extra Testing Is Needed |
|---|---|
| Capsules | Can be evaluated where permitted and application-appropriate. QA teams should confirm regulatory suitability, low-dose blend uniformity, flowability, capsule-shell compatibility, and excipient interaction. |
| Tablets | Compression behavior, segregation risk, low-dose uniformity, and excipient compatibility should be tested. Fine particle grades may improve dispersion but can affect flow. |
| Powder blends and sachets | Low inclusion levels require strong pre-blending procedures. Check uniformity, electrostatic behavior, odor transfer, and compatibility with hygroscopic ingredients. |
| Gummies | Requires destination-market review, syrup-phase compatibility testing, heat exposure evaluation, water activity review, and finished-product preservation validation. |
| Beverage powders | Requires extra solubility and precipitation testing. Confirm permitted use, pH compatibility, flavor impact, and sediment risk before commercialization. |
| RTD drinks | Limited water solubility creates precipitation risk. A validated solvent or premix strategy, pH study, and preservative efficacy testing are required. |
| Functional bars | Heat exposure, fat-phase distribution, and low-moisture matrix behavior should be evaluated before use. Sensory screening is recommended. |
| Softgels | Suitability depends on fill system, shell compatibility, and permitted use. Solvent interaction and migration risk should be reviewed. |
| Botanical or protein-containing formulas | Ingredient binding, microbial load, pH drift, and chelation may affect preservation strategy. Challenge testing is recommended. |
| Private label supplement projects | Use should be reviewed against destination market, product format, and customer label requirements before quotation or production. |
| Item | B2B Supply Details |
|---|---|
| Sample packing | Commonly supplied in sealed foil bags or sample bottles for lab evaluation; sample quantity confirmed by project |
| Bulk inner packing | Double polyethylene inner bags or equivalent moisture-protective liners |
| Bulk outer packing | 25 kg fiber drum or carton/drum configuration according to order size |
| Label information | Product name, batch number, net weight, manufacture date, retest or expiry date, storage condition, and handling marks |
| Palletization | Export pallets available when required; pallet height and wrapping can be adjusted for sea or air shipment |
| Shelf life | Typically 24 months unopened under recommended storage conditions |
| Storage conditions | Keep sealed, dry, and protected from heat, direct sunlight, humidity, strong bases, oxidizers, and high-odor materials |
| Humidity control | Use tight sealing after opening; desiccant or enhanced packing can be discussed for humid routes |
| Temperature control | Ambient shipping is typically suitable; avoid prolonged exposure to excessive heat |
| Shipping options | Express sample shipment, air freight, sea freight, or forwarder-coordinated export shipment |
| Export documents | Commercial invoice, packing list, COA, SDS, TDS, specification sheet, origin statement, and project documents when required |
| Long-distance shipping | Moisture protection, odor segregation, drum integrity, and pallet stability are important for long sea freight lanes |
| Handling after opening | Reseal immediately, minimize open-air exposure, avoid cross-contamination, and maintain lot identity for partial use |
Propylparaben Powder should be stored in a segregated dry-chemical area rather than beside fragrances, essential oils, amines, strong bases, oxidizers, or volatile odor materials. For repacking or partial drum use, operators should control humidity, use clean utensils, reseal liners promptly, and record the remaining weight under the same batch number. For distributors and contract manufacturers, maintaining original label traceability is important for complaint investigation, retained-sample comparison, and customer documentation review.
| Item | Supply Information |
|---|---|
| Standard MOQ | Typically 25 kg; sample and pilot quantities may be available for validation projects |
| Sample policy | Samples can be arranged for formulation testing, QC approval, premix evaluation, and supplier qualification |
| Standard lead time | Commonly 7–15 business days, depending on stock, specification, and testing requirements |
| Custom specification lead time | Confirmed by project; PSD control, extended impurity testing, residual solvents, or heavy-metal tightening may require additional time |
| Bulk supply support | Drum supply, repeat-order planning, distributor support, and shipment coordination available |
| Custom manufacturing support | Particle size adjustment, assay alignment, low-impurity selection, premix-related testing, and project-specific QC packages |
| OEM / private label support | Supports contract manufacturing and private label projects where Propylparaben Powder is permitted and technically suitable |
| Available documents | COA, TDS, SDS, specification sheet, allergen statement, GMO statement, gluten statement, vegan statement, irradiation statement, country of origin statement |
| Testing support | HPLC assay, related substances, loss on drying, residue on ignition, melting range, PSD, heavy metals, microbiology, residual solvents, and solvent-phase clarity checks |
| Buyer quotation details | Target specification, intended application, order quantity, destination market, required documents, test list, packaging needs, and expected timeline |
Document availability should be confirmed during quotation because some statements, extended test reports, and market-specific declarations depend on the agreed specification, order quantity, and destination market. Pre-shipment COA review can be arranged when required, and repeat-order specifications may be aligned with approved retained samples for ongoing supply programs. Propylparaben Powder can be supplied for standard bulk purchase or custom specification projects, including particle size customization, PSD reporting, residual solvent testing, heavy metal tightening, microbiological limits, formulation guidance, OEM support, private label support, and project-specific documentation.
For a B2B quotation, please provide the target specification, application format, order quantity, destination market, document checklist, testing requirements, packaging needs, and expected timeline. If the formula is clarity-sensitive or solvent-dependent, also share the solvent phase, pH range, processing temperature, and whether PSD or time-to-clear testing should be included in the offer.
Share your target specification, application, quantity and document needs. We will help confirm suitable options, COA/TDS/SDS support and bulk supply details.
Explore related ingredients for formula comparison, complementary applications and alternative sourcing options across food, beverage, supplement and wellness projects.