

Selenium-enriched Yeast is a light yellow to tan powder produced from selenium-enriched Saccharomyces cerevisiae through controlled fermentation, inactivation, drying, milling and sieving. It is supplied for capsules, tablets, mineral premixes, sachets and selected gummies, with batch COA review, traceability and technical support for accurate low-dose formulation and commercial sourcing by supplement manufacturers and contract product developers.
| Item | B2B Specification |
|---|---|
| Product Name | Selenium-enriched Yeast |
| Alternative Names | Selenium yeast, selenium yeast powder, selenium-enriched Saccharomyces cerevisiae |
| Source | Saccharomyces cerevisiae biomass |
| Process | Selenium-enrichment fermentation, inactivation, drying, milling and sieving |
| Total Selenium / Available Strength | Reported in ppm or mg/kg and agreed before order confirmation |
| Selenium Profile | Total selenium is standard; selenium speciation is available on request |
| Grade | Food grade or supplement grade according to application |
| Appearance | Light yellow to tan fine powder |
| Particle Size | 80 mesh typical; customized particle-size control available |
| Moisture | Typically ≤6.0%, or customer-specific limit |
| Carrier | Typically supplied without an added carrier |
| Applications | Capsules, tablets, mineral premixes, sachets, gummies and chewables |
| Country of Manufacture | China, confirmed in project and shipping documents |
Selenium yeast requires tighter qualification than conventional bulk powders because elemental selenium is present at a low concentration within a yeast matrix. Formulation calculations should use the actual selenium result on the current COA rather than only the nominal grade. Particle size, bulk density, moisture and flow behavior also affect weighing accuracy, premix preparation, segregation and finished-unit uniformity.
Before sample approval, buyers should define the required selenium level, assay tolerance, particle-size target, microbiological limits, heavy-metal limits and document scope. Total selenium and selenium speciation are separate analytical requirements, so the applicable method and acceptance criteria should be agreed before supply. This specification-led approach connects the ingredient’s analytical profile with practical production controls and incoming release requirements.
Additional information about production, selenium forms and sourcing considerations is available in the selenium-enriched yeast guide.
| Physical and Chemical Test | Typical Limit or Requirement | Reporting |
| Appearance and Organoleptic | Light yellow to tan powder with characteristic mild yeast odor | Visual and sensory |
| Identification | Conforms to the approved yeast-based ingredient specification | COA |
| Total Selenium | Reported in ppm or mg/kg | Actual result |
| Selenium Assay Tolerance | Agreed before supply | Actual result |
| Selenium Speciation | Available on request | COA or separate report |
| Moisture / Loss on Drying | Typically ≤6.0% | Actual result |
| Particle Size | 80 mesh typical, or customized limit | Actual result |
| Ash / Residue on Ignition | Defined in the commercial specification | Actual result |
| Bulk Density | Reported when required for filling or premix calculations | Technical report |
| Microbiological Test | Typical Working Limit |
| Total Plate Count | ≤10,000 CFU/g |
| Yeast and Mold | ≤200 CFU/g |
| Coliforms | Defined in the commercial specification |
| E. coli | Negative in 10 g |
| Salmonella | Negative in 25 g |
| Staphylococcus aureus | Negative in 10 g when specified |
| Heavy-Metal Test | Typical Working Limit |
| Lead | ≤1.0 ppm, or destination-market limit |
| Arsenic | ≤1.0 ppm, or destination-market limit |
| Cadmium | ≤0.5 ppm, or destination-market limit |
| Mercury | ≤0.1 ppm, or destination-market limit |
| Product-Specific COA Add-on | Procurement Relevance |
| Particle-Size Distribution or D90 | Supports blending, filling and segregation-risk assessment |
| Batch Assay Trend | Helps compare selenium consistency across repeat orders |
| Bulk Density and Flowability | Supports hopper, capsule-filling and premix evaluation |
| Pesticide Multi-Residue Screen | Supports customer or destination-market approval |
| Aflatoxin and Ochratoxin A Screen | Adds contaminant control for fermentation-derived material |
| Allergen and GMO Review | Supports supplier qualification and market documentation |
| Third-Party Laboratory Testing | Provides independent verification for the submitted sample or batch |
Batch release should focus on controls that affect identity, safety, formulation accuracy and manufacturing performance. The COA should identify the product, batch reference, acceptance limits and actual results. Total selenium confirms elemental concentration, while speciation testing provides additional information about the forms present within the yeast matrix. Method, laboratory and acceptance criteria should be agreed when they are material to supplier comparison or incoming release.
Essencefield’s raw material quality process connects specification approval, COA review, incoming verification and batch release. Repeat-order programs may also compare assay, appearance, moisture and particle properties to detect meaningful variation before the ingredient enters production.
Finished-product claims remain subject to market-specific review.
| Application | Practical Formulation Considerations |
| Capsules | Confirm premix uniformity, powder flow, fill weight and selenium consistency between finished units. |
| Tablets | Evaluate segregation, compression behavior, hardness, friability, disintegration and selenium recovery. |
| Vitamin-Mineral Premixes | Match carrier particle size and density with selenium yeast and other trace minerals. |
| Powder Blends and Sachets | Review flowability, serving accuracy, dispersion and yeast-like sensory notes. |
| Gummies and Chewables | Validate addition sequence, heat exposure, selenium recovery, color and piece-to-piece uniformity. |
| Beverage Powders | Assess dispersion, sedimentation, pH compatibility and visible particles. |
| Softgels | Confirm suspension stability, fill homogeneity, sedimentation and shell compatibility. |
Selenium-enriched Yeast should not be added directly to a large production blend without a controlled premix and sampling plan. Its low inclusion level creates risks of localized selenium concentration and segregation during transfer. A compatible carrier should be selected by comparing particle size, bulk density, moisture behavior and flow characteristics.
Staged geometric dilution normally provides better distribution than direct addition, but the selected ratio must reflect batch size, weighing accuracy and blender design. Laboratory trials should be followed by commercial-scale verification because equipment geometry, conveying and discharge behavior may alter uniformity. Heat-processed formats require selenium recovery testing, while beverage and softgel systems require suspension checks. Finished-product release should use representative samples from multiple blender and filling locations.
Projects moving from ingredient selection to dosage-form development can use custom supplement formulation support for powders, capsules, tablets, gummies and related formats.
| Item | Standard B2B Support |
| Sample Packaging | Foil bags or sample bottles |
| Inner Packaging | Food-grade double polyethylene liners or equivalent moisture barrier |
| Typical Bulk Pack | Commonly 25 kg per fiber drum; alternatives confirmed by project |
| Label Information | Product name, batch number, net weight, manufacturing date, shelf life and storage conditions |
| Shelf Life | Typically 24 months in unopened original packaging |
| Storage | Store sealed in a cool, dry and well-ventilated area away from sunlight, heat and strong odors |
| After Opening | Reseal the liner immediately and protect against moisture and cross-contamination |
| Shipping | Express or air freight for samples; air or sea freight for commercial orders |
The powder should remain sealed in moisture-protective packaging during storage and transportation. Damaged liners may allow moisture absorption, caking or flowability changes that affect low-dose blending. Packaging integrity and moisture protection should be verified before long-distance shipment.
| Item | B2B Supply Information |
| Standard MOQ | Usually 25–100 kg, depending on specification, packaging and testing scope |
| Samples | Available for laboratory evaluation, document review and pilot blending |
| Lead Time | Typically 7–15 days after order and specification confirmation |
| Commercial Packaging | Commonly 25 kg per drum |
| Custom Specification | Selenium grade, assay tolerance, particle size, microbiology and heavy-metal limits |
| Standard Documents | COA, TDS, SDS and specification sheet |
| Additional Statements | Allergen, GMO, gluten, vegan, irradiation, origin and applicable facility documents |
| Third-Party Testing | Available according to the agreed sample, laboratory, method and scope |
For quotation and technical review, provide:
Agree custom assay and testing requirements before sample approval; use the current COA for formulation calculations and incoming release.
Share your target specification, application, quantity and document needs. We will help confirm suitable options, COA/TDS/SDS support and bulk supply details.
Explore related ingredients for formula comparison, complementary applications and alternative sourcing options across food, beverage, supplement and wellness projects.