Bulk vitamin C powder is a high-purity L-ascorbic acid ingredient used in dietary supplements, drink mixes, beverages, gummies, tablets, capsules, nutrition premixes and selected food applications.
For commercial buyers, purity alone does not determine whether a material is suitable. Assay method, particle size, moisture, trace metals, microbiological limits, packaging and processing stability can all affect production performance.
Essencefield supplies carrier-free crystalline L-ascorbic acid for supplement, food and beverage manufacturing. Buyers can evaluate fine or granular options, quality documents, formulation samples and bulk supply terms according to the application.
Essencefield Vitamin C Powder Supply Profile
| Item | Published supply information |
|---|---|
| Chemical name | L-ascorbic acid |
| CAS number | 50-81-7 |
| Source category | Fermentation-derived carbohydrate feedstock followed by purification and crystallization |
| Standard form | Carrier-free crystalline powder |
| Appearance | White to off-white crystalline powder |
| Assay | Typically around 99.0%–100.5%, depending on the agreed method |
| Testing methods | HPLC, titration or pharmacopeia-aligned methods reviewed by project |
| Physical options | Fine or granular |
| Solubility | Freely soluble in water |
| Typical shelf life | 24 months unopened under recommended storage conditions |
| Standard MOQ | Typically 25 kg |
| Common packaging | Fiber drum, carton or export-ready packaging; 25 kg packing commonly available |
| Core documents | Specification sheet, COA, TDS and SDS |
| Optional review | Particle size, bulk density, related substances, water activity, solution color, iron, copper and expanded elemental testing |
Essencefield may also provide allergen, GMO, gluten, vegan, irradiation and country-of-origin statements according to the selected project.
Supply note: Final specifications, testing, origin, packaging and documentation should be confirmed for the agreed supply program and lot-specific COA.
Review the current Essencefield Vitamin C Powder product information or submit a technical and commercial inquiry before supplier approval.
1. Product Identity and Form Selection
Vitamin C powder normally refers to L-ascorbic acid rather than a finished consumer supplement blend.
The Joint FAO/WHO Expert Committee on Food Additives identifies ascorbic acid as INS 300. Its reference specification lists CAS 50-81-7, molecular formula C₆H₈O₆ and formula weight 176.13. It describes the ingredient as a white to slightly yellow crystalline powder that is freely soluble in water.
The official JECFA specification for ascorbic acid lists an assay of not less than 99% on the dried basis. A commercial purchase specification may apply tighter or additional limits according to the application.
Food and beverage projects
Food-grade material should meet the specification required for the intended market and food category.
In the United States, 21 CFR 182.3013 identifies ascorbic acid as generally recognized as safe when used according to good manufacturing practice.
The U.S. Food and Drug Administration also recognizes technical functions including:
- Antioxidant
- Nutrient supplement
- Dough strengthener
- pH-control agent
- Sequestrant
- Stabilizer
In the European Union, ascorbic acid is identified as E300. Permitted use can depend on the food category and conditions of use. Regulatory teams should verify the intended application in the current European Commission Food Additives Database.
Supplement and pharmacopeial projects
Supplement and pharmaceutical buyers may require testing aligned with USP, FCC, Ph. Eur., BP or a customer-defined specification.
The RFQ should identify the required monograph and any application-specific limits. A general phrase such as “pharmaceutical grade” does not define:
- The assay method
- The reporting basis
- The impurity profile
- Elemental limits
- Required documentation
- Retest or expiry expectations
Essencefield states that HPLC, titration or pharmacopeia-aligned assay methods can be reviewed according to the project. This does not mean every supply program automatically complies with every pharmacopoeia.
Fine versus granular ascorbic acid
| Physical form | Potential advantage | Main factor to validate |
|---|---|---|
| Fine powder | Rapid dispersion and good distribution at lower inclusion levels | Dust, caking and reduced flow |
| Standard crystalline powder | Balanced handling and dissolution | Compatibility with the production process |
| Granular material | Improved flow for filling, sachets and tablets | Dissolution and blend uniformity |
| Coated material | Added protection from heat, moisture or reactive ingredients | Active percentage, coating composition and release behavior |
Particle-size descriptions should be supported by an agreed sieve range or particle-size distribution. Bulk density may also be required for capsule filling, sachet packing or tablet manufacturing.
L-ascorbic acid should not be confused with mineral ascorbates, coated forms or ascorbyl palmitate. These materials differ in acidity, molecular weight, solubility and processing behavior.
For lipid-containing formulations, review Essencefield’s Ascorbyl Palmitate formulation guide.
2. Specifications and COA Review
A useful purchase specification should control both chemical quality and manufacturing performance.
| Parameter | Procurement significance |
|---|---|
| Identification | Confirms that the correct chemical material is being supplied |
| Assay | Determines active input and label calculations |
| Assay method | Enables meaningful comparison between suppliers and batches |
| Appearance | Helps identify discoloration or contamination |
| Loss on drying | Supports moisture and caking control |
| Related substances | Monitors process impurities and degradation |
| Particle size | Controls flow, dissolution and segregation |
| Bulk density | Influences filling behavior and package volume |
| Solution color and clarity | Important for clear beverages and water-phase systems |
| Iron and copper | Relevant to oxidation-sensitive formulations |
| Heavy metals | Must meet the destination market and risk assessment |
| Microbiology | Supports food, supplement or cosmetic quality requirements |
Confirm the product and batch
The COA should match the product and lot being evaluated. Check:
- Product name
- Grade
- Batch number
- Manufacturing or release date
- Retest or expiry date
- Release status
A representative COA can support preliminary evaluation, but the commercial shipment should be accompanied by a lot-specific certificate.
Separate limits from actual results
The document should clearly distinguish between specification limits and batch results.
Numerical reporting is more useful than a general “passes” result when QA or procurement teams need to monitor variation over time.
Verify the assay basis and method
Determine whether the result is:
- Reported as received
- Corrected for moisture
- Reported on a dried basis
- Tested by HPLC, titration or another approved method
Two suppliers may report similar assay values using different methods or calculation bases.
Match testing to the application
A standard test panel may not answer every formulation question.
Clear beverages may require solution color and tighter iron or copper review. Tablets may require bulk-density and flow data. Gummies, hot-fill beverages and other heat-processed products require retained-assay testing after processing.
Essencefield’s Raw Material Quality and Traceability process describes controls covering supplier qualification, specification approval, COA review, incoming inspection, material release and batch traceability.
3. Stability and Application Selection
The principal stability risks for L-ascorbic acid are oxygen, heat, moisture, light, increasing pH and catalytic iron or copper.
Transition metals may enter the formulation through mineral premixes, process water, equipment or other raw materials. Their impact can become significant in aqueous and color-sensitive systems.
Practical stability controls
- Keep bulk material sealed, dry and protected from light.
- Minimize humidity exposure after opening.
- Use clean, dry and non-reactive handling tools.
- Review compatibility with iron, copper and mineral salts.
- Add the ingredient at the lowest practical temperature in heat-processed systems.
- Reduce unnecessary air incorporation.
- Measure retained assay after processing.
- Test potency throughout the proposed shelf life.
- Evaluate the final commercial package rather than only laboratory containers.
- Establish overage from stability data instead of using an arbitrary percentage.
Application selection matrix
| Application | Supply direction | Critical checks |
|---|---|---|
| Powdered beverage | Fine or standard crystalline material | Dissolution, acidity, flavor and segregation |
| Ready-to-drink beverage | Application-tested material | Oxygen, heat, solution color and retained assay |
| Capsule | Fine or granular material | Flow, fill-weight variation and blend uniformity |
| Tablet | Granular or process-matched grade | Compressibility, hardness and disintegration |
| Gummy | Food-grade, process-tested material | Heat, pH, water activity and potency retention |
| Stick pack | Flow-matched fine or granular grade | Filling consistency, dust and moisture barrier |
| Nutrition premix | Particle-size-matched ingredient | Density differences and segregation |
| Bakery | Food-grade ascorbic acid | Dose response and dough performance |
| Cosmetic water phase | Application-specific material | pH, oxidation and solution color |
In bakery systems, ascorbic acid may function as a dough strengthener. Dosage should be validated against flour characteristics, mixing conditions and target dough performance.
4. Supplier Approval and Documentation
Supplier approval should consider the complete quality and supply system rather than price and assay alone.
Supplier controls
Procurement and QA teams should review:
- Production-resource identity
- Country of origin
- Specification control
- Batch traceability
- Analytical capabilities
- Change notification
- Complaint and corrective-action support
- Retained-sample practices
- Commercial capacity
- Lead-time consistency
Document package
| Category | Typical documents |
|---|---|
| Product definition | Specification sheet and TDS |
| Batch quality | COA and applicable test reports |
| Safety | SDS |
| Compliance | Required allergen, GMO, gluten, vegan or irradiation statements |
| Supply-chain support | Country of origin and manufacturing-flow information |
| Additional verification | Third-party laboratory reports when required |
The document package should reflect the application and destination market. Requesting unnecessary documents can delay approval without improving risk control.
Approval process
A practical approval path is:
Specification review → representative sample → application test → commercial terms → lot-specific COA → batch release
The sample should represent the same grade, production source and physical specification proposed for commercial supply.
5. Packaging, MOQ and Total Cost
Essencefield lists sealed sample bags or aluminum foil bags for product evaluation.
Bulk packaging may use double PE liners, aluminum foil liners or other moisture-barrier inner packaging inside fiber drums, cartons or export-ready outer formats. A 25 kg bulk format is commonly available.
The published standard MOQ is typically 25 kg, while smaller quantities may be discussed for formulation trials and supplier approval.
Lead time depends on:
- Current availability
- Order volume
- Testing scope
- Particle-size requirements
- Packaging
- Third-party analysis
- Export documentation
- Destination country
Compare cost per usable kilogram
The lowest price per kilogram is not always the lowest manufacturing cost.
A total-cost comparison should include:
- Assay-adjusted active cost
- Freight and import duties
- Incoming testing
- Dust and processing loss
- Required stability overage
- Supply-interruption risk
Assay-adjusted cost can be estimated as:
Delivered price per kilogram ÷ assay fraction
For example, material assaying at 99% should be evaluated using 0.99 as the active fraction.
A higher-priced granular grade may still reduce total cost when it improves filling speed and lowers dust loss.
6. Request a Specification, Sample or Quote
To support an accurate technical review and quotation, provide:
- Intended application
- Required grade or standard
- Preferred particle size
- Trial quantity and annual volume
- Destination market
- Required documents or tests
- Packaging preference and delivery date
Essencefield’s contact and project inquiry page accepts specifications, formulas, labels, reference images and related project files.
Request the following before commercial approval:
- Current Vitamin C Powder specification
- Representative COA
- Sample availability
- Applicable testing options
- Packaging and MOQ
- Estimated lead time
- Bulk quotation
Request the current specification, representative COA, sample and bulk pricing from Essencefield.