DL-alanine powder is the racemic form of alanine, containing both D-alanine and L-alanine. It is identified by CAS No. 302-72-7 and is typically supplied as a white to off-white crystalline powder.

For procurement and quality teams, advertised purity is not enough to approve the material. The purchasing specification should also define stereochemical identity, assay basis, moisture, inorganic residue, particle size, relevant impurities, analytical methods, and destination-market requirements.

Essencefield supplies DL-alanine powder for bulk ingredient projects using specifications matched to the intended application, testing scope, physical requirements, and commercial quantity.

DL-Alanine Powder Technical Summary

ItemTechnical reference
Product identityDL-Alanine
CAS number302-72-7
CompositionRacemic mixture of D-alanine and L-alanine
Molecular formulaC₃H₇NO₂
Molecular weight89.09 g/mol
Typical appearanceWhite to off-white crystalline powder
Core quality controlsIdentity, assay, moisture, inorganic residue, particle size, impurities, and contaminants
Stereochemical reviewSpecific rotation for screening; chiral testing when direct confirmation is required
Core purchasing documentsApproved specification, batch COA, TDS, and SDS

A high assay result does not independently prove the correct stereochemical form, acceptable impurity profile, or suitability for a particular finished product.

What Is DL-Alanine Powder?

Alanine is an alpha-amino acid with a chiral carbon atom. It therefore exists as two mirror-image forms:

  • D-alanine
  • L-alanine

DL-alanine contains both forms as a racemic mixture rather than one isolated enantiomer.

The PubChem DL-alanine record identifies the substance as racemic alanine. The FAO/WHO Joint Expert Committee on Food Additives, commonly known as JECFA, lists CAS No. 302-72-7, molecular formula C₃H₇NO₂, and molecular weight 89.09.

PropertyIdentification
Product nameDL-Alanine
Chemical nameDL-2-aminopropanoic acid
Chemical classAlpha-amino acid
Stereochemical formRacemic D/L mixture
Water behaviorSoluble under normal formulation conditions
JECFA number1437
FEMA number3818

JECFA describes DL-alanine as an odorless white crystalline powder that is soluble in water and slightly soluble in ethanol. Its flavouring specification lists a minimum assay of 98%.

That value belongs to the JECFA DL-alanine flavouring specification. It should not automatically be treated as the default commercial release limit for every grade or supplier.

DL-Alanine vs. L-Alanine, D-Alanine, and Beta-Alanine

“Alanine” alone is not a sufficiently precise description for a purchase order, specification, or warehouse label.

IngredientChemical formCAS numberMain procurement risk
DL-AlanineRacemic mixture of D- and L-alanine302-72-7Incorrect D/L composition
L-AlanineIsolated L-enantiomer56-41-7Substitution for racemic material
D-AlanineIsolated D-enantiomer338-69-2Incorrect stereochemical form
Beta-AlanineStructurally different beta-amino acid107-95-9Confusion with alpha-alanine

L-alanine and DL-alanine share the same molecular formula, so molecular formula alone cannot establish the commercial identity. Beta-alanine is structurally different because the amino group occupies another position in the molecule.

For additional comparison, Essencefield’s L-alanine and beta-alanine differences guide explains how identity, optical properties, and application positioning differ among related alanine ingredients.

The selected material should remain consistent across the:

  • Formulation record
  • Purchase order
  • Approved specification
  • Certificate of analysis
  • Safety data sheet
  • Warehouse label
  • Commercial invoice
  • Shipping documents

Any mismatch between the product name and CAS number should be resolved before sampling or production.

How to Review a DL-Alanine Specification and COA

A purchasing specification establishes the acceptance criteria. A certificate of analysis reports the results for one production lot.

A COA should therefore be assessed against an approved specification rather than treated as a standalone guarantee.

ParameterWhat it verifiesWhat to check
IdentificationCorrect chemical identityMethod, reference, and result
AssayDL-alanine concentrationMethod, calculation basis, limit, and actual result
AppearancePhysical consistencyColor, form, and visible contamination
Loss on dryingMoisture and volatile matterResult, limit, temperature, and test duration
Residue on ignitionInorganic residueMethod and maximum limit
Particle sizeBlending and processing behaviorMesh or particle-size distribution
Bulk densityFill volume and segregation riskLoose or tapped density where relevant
pHCompatibility in aqueous systemsTest concentration and method
Chloride and sulfateIonic process impuritiesDefined limits and actual results
Related substancesOrganic impurity profileIndividual and total limits
Heavy metalsElemental contaminant controlMarket-specific limits
MicrobiologyHygienic qualityApplication-appropriate test panel
Specific rotationRacemic screening trendMethod, conditions, and result
Chiral compositionD/L identityEnantiomer-specific testing when required

Essencefield’s public product information does not present one universal numerical assay, microbiological panel, or heavy-metal specification for every DL-alanine order. Final release criteria are established through the approved project specification.

Assay Basis

A purity percentage is meaningful only when its analytical basis is defined.

The specification should state whether assay is:

  • Reported as received
  • Calculated on a dry basis
  • Determined by titration
  • Determined chromatographically
  • Controlled as a minimum value
  • Controlled within a defined range

Two suppliers may both market high-purity DL-alanine powder while using different methods or moisture corrections. The analytical basis and actual lot result are therefore more useful than the headline percentage alone.

Physical and Impurity Controls

Loss on drying primarily measures moisture and other volatile matter removed under defined conditions. Excessive moisture may contribute to caking, flow variation, inaccurate dosing, or lower as-received assay.

Residue on ignition measures nonvolatile inorganic material remaining after the organic portion is removed. It can help evaluate purification consistency and inorganic contamination.

Particle size and bulk density are also commercially important. A chemically compliant batch may still perform poorly if its physical properties cause:

  • Blend segregation
  • Excessive dusting
  • Irregular hopper flow
  • Variable capsule fill
  • Poor sachet dosing
  • Slow dissolution

Where these characteristics affect production, they should be included in the purchasing specification rather than left as informal observations.

Complete Batch Reporting

A useful COA includes:

  • Product name and code
  • Batch or lot number
  • Manufacturing date
  • Expiry or retest date
  • Specification limits
  • Actual analytical results
  • Test methods or references
  • Release date
  • Authorized approval

“Conforms” may be acceptable for a qualitative identity test. Quantitative tests should normally report a numerical result.

Essencefield’s testing and certification process explains how product identity, batch references, methods, acceptance criteria, and actual results should connect within the supporting documentation. Independent third-party testing can also be discussed when required by a project.

Specific Rotation and Chiral Confirmation

A standard chemical identity test may confirm alanine without determining the proportion of its D and L forms.

Specific rotation can support screening of the material’s optical behavior. However, near-zero rotation should not be presented as independent proof of an exact 50:50 D/L composition when stereochemical identity is critical.

Analytical controlMain purposeLimitation
Chemical identificationConfirms alanine identityMay not measure D/L proportions
Specific rotationScreens optical behaviorDoes not always establish the exact enantiomer ratio
Chiral chromatographySeparates and measures enantiomersRequires an appropriate validated method
Batch trend reviewAssesses long-term consistencyDepends on reliable historical results

Chiral HPLC or another enantiomer-specific method may be appropriate when:

  • A new manufacturing source is being qualified
  • A supplier or production route has changed
  • The customer specification requires D/L confirmation
  • The final process is stereochemically sensitive
  • Specific-rotation results show unexpected variation
  • Registration documents require stronger evidence

Essencefield lists specific rotation as a possible screening control and chiral confirmation as an option for projects requiring direct evidence of D/L composition.

Grade and Regulatory Scope

Terms such as food grade, supplement grade, or formulation grade are incomplete unless they are supported by a measurable specification, suitable manufacturing controls, appropriate documentation, and a valid legal basis for the intended use.

Manufacturing compatibility does not establish regulatory authorization.

United States

The current 21 CFR §172.540 provision identifies DL-alanine as a racemic mixture of D- and L-alanine with CAS No. 302-72-7.

It permits DL-alanine as a flavor enhancer for sweeteners in pickling mixtures at a level not exceeding 1% of the pickling spice added to the brine.

This is a specific condition of use. It should not be interpreted as unrestricted authorization for all foods, beverages, dietary supplements, or other finished products.

For another application, the responsible business needs to establish the legal basis for the intended:

  • Finished-product category
  • Technical function
  • Use level
  • Label declaration
  • Market positioning
  • Destination country

JECFA and Other Markets

JECFA provides an internationally recognized identity and purity reference for DL-alanine as a flavouring substance. Its specification is useful for technical comparison but does not independently authorize every application in every jurisdiction.

Before commercial use, regulatory teams should review local substance listings, use restrictions, purity criteria, labeling rules, and import requirements.

Formulation Compatibility

Analytical compliance and manufacturing suitability should be evaluated separately.

FormatMain properties to evaluate
Capsules and tabletsParticle size, bulk density, flowability, compression, and fill consistency
Powder blends and sachetsBlend uniformity, dusting, caking, and dosing accuracy
Beverage powdersDissolution, pH interaction, taste, and sediment
Gummies or heated formatsHeat exposure, water activity, pH, and color development

A successful solubility test in water does not prove acceptable behavior in a commercial matrix containing acids, electrolytes, proteins, sweeteners, flavors, or other amino acids.

Pilot testing should use the proposed commercial grade and realistic process conditions.

DL-Alanine Supplier Qualification

Supplier approval should connect source identity, written specifications, batch evidence, document scope, and long-term change control.

Essencefield’s raw material quality framework follows the sequence of supplier qualification, specification approval, COA review, incoming inspection, material release, and batch traceability.

Qualification stageMinimum evidence
Source confirmationManufacturer, site, country of origin, and product code
Specification approvalDefined limits, methods, units, and reporting bases
Batch reviewRepresentative COAs from recent production lots
Document verificationValid certificates matching the relevant company and facility
TraceabilityConnection between source material, batch, testing, and shipment
Change controlAdvance notice of changes to site, process, specification, method, or packaging

One favorable sample COA does not demonstrate long-term consistency. Where continuity matters, several recent lots should be compared for assay, moisture, particle size, inorganic residue, specific rotation, and key impurity results.

Verified Essencefield Supply Information

The current Essencefield product page provides the following representative supply references:

Commercial itemPublished reference
AppearanceWhite to off-white crystalline powder
CarrierTypically carrier-free unless supplied in a custom premix
Particle sizeStandard options; customization can be discussed
Evaluation sampleAvailable for qualified projects
Inner packingFood-grade PE or moisture-barrier liner
Outer packingCarton or fiber drum
Common bulk pack25 kg
Typical MOQFrom 25 kg, subject to specification and stock
Standard lead timeCommonly 7–15 working days
Typical shelf life24 months unopened under recommended conditions
DocumentsCOA, TDS, SDS, specification, and applicable declarations
Additional testingImpurity, contaminant, microbiological, or chiral testing by project

These figures are website references rather than unconditional commercial guarantees. Final specifications, packaging, MOQ, testing, lead time, and document availability should be confirmed in the quotation and approved order documents.

DL-Alanine RFQ Checklist

A complete request for quotation should include:

  1. Product name and CAS number
  2. Intended application and destination market
  3. Required grade or reference standard
  4. Target assay and impurity limits
  5. Particle-size or physical-property requirements
  6. Order quantity and annual forecast
  7. Required analytical tests and documents
  8. Packaging, Incoterm, and delivery schedule

An existing specification or competitor COA can be submitted for comparison. This helps identify differences in assay basis, test methods, physical properties, impurity limits, and document scope before a sample is approved.

Conclusion

DL-alanine powder should be selected through identity-led and specification-led review rather than advertised purity alone.

A defensible approval process confirms the correct alanine form, defines analytical and physical requirements, determines whether chiral testing is necessary, verifies regulatory suitability, and compares representative batch evidence.

For current specifications, samples, documentation, and commercial terms, submit the project details through the Essencefield ingredient inquiry page.

Request a Manufacturing Quote

Please use the form below to share your ingredient requirements—product category, target application, desired specifications (e.g., assay/ratio, mesh size, carrier), and estimated order quantity. If you need OEM/private label, include dosage form and key label claims. We’ll route your request to the right team and recommend suitable ingredients, testing/documentation options, packaging, and lead times. You’ll receive indicative pricing, MOQ, and a sample/approval plan.

Picture of Essencefield Editorial Team | Ingredient Science, Quality & OEM Manufacturing

Essencefield Editorial Team | Ingredient Science, Quality & OEM Manufacturing

We publish technical guides for B2B sourcing and formulation of botanical ingredients, including typical COA/Spec ranges, risk-based testing plans, documentation, and OEM/private-label manufacturing. Content is reviewed to align with manufacturing feasibility, batch traceability, and quality control practices used for global export projects.

Reviewed By: Essencefield QA & Technical Team (Quality System)

Documents (on request): COA · TDS/Spec · SDS · Allergen/GMO statements · Regulatory declarations (market-dependent)

More Posts